T082 - Dell PowerVault ML6000 Maintenance Manual

Tape library
Hide thumbs Also See for PowerVault ML6000:
Table of Contents

Advertisement

T082

T082 - Barcode Scanner Failure
Description
Detection Scenarios
Root Causes
Service Resolution
Steps
Possible CRUs/FRUs
PowerVault ML6000 Maintenance Guide
GUI Description: The library barcode scanner is not operating properly.
Explanation: The barcode scanner is detected to be in a state where the
library control logic cannot use it. Library robot power is known to be applied
(door is closed and robot is detected to be functioning enough to confirm that
power is applied), but scanner communication cannot be established at all or
appears to be not healthy.
• During any library bootup or door close operation, picker power is applied
and barcode scanner communication is established.
• During run-time operations such as inventory, where the barcode scanner is
used.
• Scanner is physically disconnected.
• Various electrical hardware failures that prevent proper communication
between LCB and barcode scanner.
• Barcode scanner is not functioning properly.
1 Perform
RR004 - Remove and Replace Picker Assembly
also
Removing and Replacing the Robot Assembly
2 Clear the RAS ticket. Power down the library. Open the main door and
inspect the flex cable on top of the picker to determine if it is loose or not
seated properly.
Note: Read and perform all resolution steps before dispatching any parts.
Dispatch the first part listed below for replacement. If this does not solve the
problem, dispatch the second part, and so on, in order. Dispatch only one part
(or set of parts) at a time.
1 Picker Assembly (if Model 1 robot is installed) or
Robot Assembly (if Model 2 robot is installed)
2 Cable Spool
3 Y-carriage Assembly (if Model 1 robot is installed)
on page 422. See