Millivolt Board Installation - kozy heat PRINCETON RPC-36 Installation And Optimization Manual

Direct vent
Table of Contents

Advertisement

WARNING: DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET (LOCATED UNDER THE MILLIVOLT BOARD) IN
PLACE. IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
1.
Place millivolt board in firebox, aligning the holes in the millivolt board with
holes in the firebox bottom.
MAKE SURE SEALING GASKET IS IN PLACE ON FIREBOX BOTTOM!
Secure millivolt board to firebox bottom with the (8) screws previously
removed.
2.
Place venturi spacers onto venturi mounting studs.
3.
Re-install front burner assembly, making sure burner tube is positioned over
burner orifice. Secure with screws.
4.
Reinstall back burner/log grate assembly by positioning burner tube into ven-
turi collar on millivolt board and pilot assembly through rectangular opening.
Secure front left and back right legs with screws.
5.
Reinstall pilot shield.
6.
Reinstall ember refractory.
7.
Reinstall log set. (Pages 31-33).
8.
Reconnect gas line to manual shut-off valve.
9.
Model PRC-36: Reconnect any wall switch, remote control or thermostat
wires to the top & bottom terminals on the gas valve.
Model PRC-36-RF: Re-connect the (2) wires to fan cord. Plug fan cord into
receptacle.
10. Reinstall glass frame assembly. Page 15.
11. Reinstall upper louver & upper hood. Page 36.
12. Turn gas on.
13. Verify proper log placement, operation of fireplace, and any electrical
components.
CAUTION: CHECK ALL CONNECTIONS FOR LEAKS,
WHETHER FIELD OR FACTORY MADE.
BURNER LOG GRATE ASSEMBLY
FRONT BURNER ASSEMBLY

MILLIVOLT BOARD INSTALLATION

PILOT SHIELD
RE-CONNECT ANY REMOTE /
THERMOSTAT WIRES
PAGE 35
INSTALL (8) SCREWS
INSTALL (2) SCREWS
INSTALL (2) SCREWS