Horizontal Vent Heat Shield Installation; Nailing Flange Assembly & Installation - kozy heat PRINCETON RPC-36 Installation And Optimization Manual

Direct vent
Table of Contents

Advertisement

HORIZONTAL VENT HEAT SHIELD INSTALLATION

IMPORTANT: THE HORIZONTAL VENT HEAT SHIELD MUST BE INSTALLED WHEN USING A 45-DEGREE ELBOW TO
HORIZONTALLY POSITION THE VENT SYSTEM.
EXCEPTION: CORNER INSTALLATIONS
To Install Horizontal Vent Heat Shield:
1.
Loosen, but do not remove center three screws at the back of
fireplace.
2.
Bend the horizontal heat shield at perforation to a 45° angle.
Slide (3) slots on horizontal vent heat shield under loosened
screws. Re-tighten screws.
NAILING FLANGE ASSEMBLY & INSTALLATION
1.
Remove the (4) nailing flanges from fireplace sides.
2.
With the 1/4" (6 mm) stand-offs on the nailing flanges facing away from fireplace, align nailing flange with the holes on the outside cor-
ners of fireplace. Secure with screws (provided in installation manual parts packet) through the slots in the nailing flanges .
3.
Bend perforation on nailing flange until parallel with fireplace face. Do not bend toward fireplace face.
4.
Position framing stud against 1/4" (6 mm) stand-offs located on the backside of nailing flanges. Secure with nails or screws.
NOTE: Depending on facing material, tabs can be adjusted
forward or back up to 1/2" (13 mm).
When installed, nailing flanges provide the minimum 1/4" (6 mm) clearance from fireplace sides.
AS SHIPPED
CAUTION: NEVER PERMANENTLY REMOVE THESE ASSEMBLIES FROM
THE FIREPLACE - THEY MUST BE SECURED IN PLACE REGARDLESS OF
FINISH MATERIAL USED.
PREPARE THE FIREPLACE
NAILING FLANGES
INSTALLED
Attach here. Tighten screws.
1/4" (6mm)
CLEARANCE
PAGE 10
1/4" (6mm)
CLEARANCE
FRONT VIEW
NAILING FLANGE
FRAMING STUD
TOP VIEW
STAND-OFF
FRAMING STUD
NAILING FLANGE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Princeton rpc-36-rf

Table of Contents