6. Function Parameters

6.1 Setting and Changing Function Parameters

Parameters can be set and monitored in Custom Mode and Function Setting
Mode. Be sure to change and set various function parameters in stop status.
And note that some function parameters can be changed during operation.
6.1.1 Setting and Changing Function Parameters in
Stop Status
Setting Example
Change the maximum output frequency from 50.0 Hz to 60.0 Hz (change
setting value of parameter P008 from "50.0" to "60.0").
1. Press
button to stop the inverter.
2. Press
button five times to select Function Setting
Mode.
(If a password is set beforehand, please enter it. Refer to
parameter P150.)
3. Press
button seven times to change parameter No.
to "P008".
4. Press
button to display setting value of parameter
P008.
(The display part is flickering.)
5. Press
button to change the displayed value to "60".
(The display part is flickering.)
6. Press
button to apply the value.
7. Press
button.
(If the built-in memory setting mode is set to "conceal",
the inverter enters "operation ready" status.)
82