Operation When P004 Is Set To “8” - Panasonic VF200 Instruction Manual

Table of Contents

Advertisement

Appendix Function Parameter List
■ Operation when P004 is set to "8"
· The basic operation is the same as the operation when P004 is set to "0", but
the operation will continue instead of triggering OP trip even if the operation
panel is removed.
·The value prior to operation panel removal is used as frequency setting.
·The following operation procedures must be performed when frequency is
changed with the potentiometer after the operation panel is reinstalled.
1) Press MODE button to switch to "Frequency Setting Mode (Fr)".
2) Press SET button.
As the frequency data flickers, it can be changed with the potentiometer.
3) Press SET button to change frequency data with the potentiometer.
After the changed frequency data is applied, acceleration or deceleration
operation will start with new setting value. Thus the frequency can be changed
with the potentiometer.
146