P031
DC Brake Time
DC Brake Level
P032
DC brake can be applied when the inverter output frequency drops below
"P030: Stop Frequency" during ramp-to-stop.
In addition, positioning control can be performed combining with JOG
operation.
■
Parameter P031: DC Brake Time
Data setting range (s)
* The DC brake is not applied when "0000" is set.
■ Parameter P032: DC Brake Level
Data setting range (s)
* The setting increment is "5". The larger the
value is, the stronger the braking force is.
・The frequency for applying the DC brake is set by parameter "P030: Stop
Frequency".
・DC brake during the switching between forward run and reverse run is set
with parameter "P033: Stop Frequency during Forward/Reverse Run
Operation", "P034: DC Brake Time during Forward/Reverse Run Operation"
and "P035: DC Brake Level during Forward/Reverse Run Operation".
Related parameter: P030
0000·0.1 to 120.0
0 to 100
Appendix Function Parameter List