Panasonic VF200 Instruction Manual page 201

Table of Contents

Advertisement

Appendix Function Parameter List
■ Setting value = "1": Example of multi-speed frequency operation function
Up to sixteen levels of frequency can be selected, switched and controlled by
4 button signals.
st
nd
th
(The 1
speed: setting signal of P004, the 2
to 16
speed: setting frequency
of P046 to P060)
・Set any 4 buttons of SW1 to SW5 to multi-speed function buttons.
(When setting of P036 to P040 is "0")
・With this function, 1 button, 2 buttons and 3 buttons are used to input 2-step
speed, 4-step speed and 8-step speed respectively.
nd
th
・The inverter will stop (0 V stop) when the 2
to 16
speed frequency (P046
to P060) are set to "0000" and this multi-speed frequency is selected.
194

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents