Appendix Function Parameter List
■ Setting value = "3": Example of acceleration/deceleration linked with
multi-speed frequency operation
nd
rd
The 2
, 3
and 4
acceleration/deceleration by using two SW signals.
・Set any 2 buttons of SW1 to SW5 to multi-speed function buttons.(When
setting of P036 to P040 is "0")
st
・The 1
speed is command value of frequency setting signal set with
parameter P004.
st
・The 1
acceleration time is set with parameter P001.
st
The 1
deceleration time is set with parameter P002.
nd
th
・The 2
to 16
nd
th
The 2
to 4
acceleration/deceleration time is set with parameter P061 to
P066.
Related parameters: P036 to P041, P046 to P066
196
th
speed can be linked (combined) with the 2
speed frequency can be set with parameter P046 to P060.