MAP 0400: FRU failure analysis
124
SAN140M Installation and Service Manual
This MAP describes fault isolation for product FRUs. The failure
indicator is:
•
Illumination of the associated amber LED.
•
Event codes observed at the Event Log (EFCM Basic Edition or
Element Manager interface).
1
Table 13
lists event codes, explanations, and MAP steps.
MAP 400: Event codes
Table 13
Event
Explanation
code
300
Cooling fan propeller failed.
301
Cooling fan propeller failed.
302
Cooling fan propeller failed.
303
Cooling fan propeller failed.
304
Cooling fan propeller failed.
305
Cooling fan propeller failed.
414
Backup CTP card failed.
420
Backup CTP card NV-RAM failure.
426
Multiple ECC single-bit errors occurred.
433
Non-recoverable Ethernet fault.
440
Embedded port hardware failed.
604
SBAR assembly failure.
605
SBAR assembly revision not supported.
607
Director contains no operational SBAR assemblies.
620
SBAR fan failure.
805
High temperature warning (SBAR assembly thermal
sensor).
Action
Go to
step
3.
Go to
step
3.
Go to
step
3.
Go to
step
3.
Go to
step
3.
Go to
step
3.
Go to
step
6.
Go to
step
6.
Go to
step
4.
Go to
step
6.
Go to
step
6.
Go to
step
8.
Go to
step
7.
Go to
step
8.
Go to
step
8.
Go to
step
8.