installation
|
24
HORIZONTAL TERMINATIONS
FLEX VENT 5" X 8"
These venting systems, in combination with the B41XTCE Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent
Termination Locations" section.
Regency
Direct Vent (Flex) System 4 foot Termination Kit (Part# 946-615) or 10 foot Termination Kit (Part# 946-616) includes all the parts
®
needed to install the B41XTCE with a either a top or rear vent.
FPI Kit #
Length Contains:
1)
#946-615
4 Feet
2)
3)
4)
#946-618
6 Feet
5)
6)
7)
#946-616
10 Feet
8)
9)
10) vinyl siding standoff
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency may be used for Flex installations.
3) Regency
Direct Vent System (Flex) is only approved for horizontal terminations.
®
NOTE: If longer runs are required the FPI Direct Vent system (Flex) #946-616 includes
all parts needed to install the B41XTCE with a maximum 10' run.
24 |
Regency Bellavista™ B41XTCE-10 Gas Fireplace
8" flexible liner (Kit length)
5" flexible liner (Kit length)
spring spacers
thimble
AstroCap XL termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 1-1/2" drill point
IMPORTANT
Must use Rear Venting Deflector
packaged with unit in rear vent
horizontal termination applications.