www.regency-fi re.com
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
918-759a
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
B36X
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
Owners &
Installation Manual
MODEL: B36X
Medium DV Gas Fireplace
05/02/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bellavista B36X and is the answer not in the manual?

Questions and answers

Summary of Contents for Regency Bellavista B36X

  • Page 1 Owners & Regency Bellavista B36X ™ Installation Manual Gas Fireplace MODEL: B36X Medium DV Gas Fireplace www.regency-fi re.com FOR YOUR SAFETY WARNING: What to do if you smell gas: If the information in these instructions are not followed exactly, Do not try to light any appliance a fi...
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The Bellavista™ B36X has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch.
  • Page 3: Manufactured Mobile Home Requirements

    This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. Ensure that structural members are not cut or weakened during installation. Regency Bellavista™ B36X Gas Fireplace...
  • Page 4: Table Of Contents

    The Warranty: Limited Lifetime ........63 Vertical Termination With Co-linear Flex System ..31 Venting Arrangement - Vertical Terminations ....32 Unit Installation with Horizontal Termination ....33 Unit Installation ............34 Unit installation with Vertical Termination ....35 Gas Line Installation ............35 Regency Bellavista™ B36X Gas Fireplace...
  • Page 5: Safety Label

    The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed. Regency Bellavista™ B36X Gas Fireplace...
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Bellavista™ B36X Gas Fireplace...
  • Page 7: Dimensions

    DIMENSIONS UNIT DIMENSIONS 33” (838mm) 35-1/4” (895mm) 30-3/8” (762mm) 39-1/16” (992mm) 21”(533mm) 37-1/2” (953mm) 1”(25.4mm) 36” (914mm) 33-1/16” (840mm) 35-1/4” (895mm) 26-1/2” (673mm) 17-5/16” (440mm) 19-5/16” (490mm) 20-1/4” (514mm) 39” (991mm) Full Screen Doors Regency Bellavista™ B36X Gas Fireplace...
  • Page 8: Installation

    fi replace. 9) Wear gloves and safety glasses for protection while doing required maintenance. 10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination. Regency Bellavista™ B36X Gas Fireplace Regency Bellavista™ B36X Gas Fireplace...
  • Page 9: Installation Checklist

    . F a n I n s t a l l a t i o n ( O p t i o n a l ) 6) Final check. Diagram 1 Flat on Wall Corner Recessed into Wall/Alcove Corner Regency Bellavista™ B36X Gas Fireplace...
  • Page 10: Clearances

    D: Mantel Depth 12" (304mm) 14-1/2 " (368mm) from Top of Fireplace Opening E: Alcove Width 84" (2134mm) Sidewall to Sidewall (Minimum) F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) Notes: 0" No Hearth Required Regency Bellavista™ B36X Gas Fireplace...
  • Page 11: Mantel Clearances

    Mantel Clearances B36X From Top of Fireplace 32" 14-1/2" 11" 6-1/2" Opening (813mm) (368mm) (279mm) (165mm) MANTEL LEG CLEARANCES 12” Side Wall (Measured from side of Fireplace Opening) Top View 2" 5" Allowable mantel leg projection. Regency Bellavista™ B36X Gas Fireplace...
  • Page 12: Framing

    Top Header Combustible Facing 11" (279mm) dia. Hole through wall Vent. Opening for gas connection Note: If installing the unit into a corner and rear venting - use AstroCapXL 946-623/P to obtain closest clearance. Regency Bellavista™ B36X Gas Fireplace...
  • Page 13: Finishing

    fi replace / nailing strips. 3/4" Finishing material - thicker Alternatively, you can use J Style Trim or Metal Corner Bead than 1-1/4" to cover cut edges of the facing material. Full Screen Door Diagram 4 Diagram 2 Regency Bellavista™ B36X Gas Fireplace...
  • Page 14: Unit Assembly Prior To Installation

    Top Facing Support Screw holes for Top Facing Support Top Facing Support "C" Screw Position: is reversed For a facing material depth of 1-1/4" (32mm), for “C” hole position the top facing support must be reversed. Regency Bellavista™ B36X Gas Fireplace...
  • Page 15: Top Flue Collar Installation

    Heat Defl ector Diagram 2 3) From inside the fi rebox, remove the baffl e plate by removing 4 - 1/4" x 1/2 " screws. See Diagram 3 Diagram 4 Baffl e Plate Diagram 3 Regency Bellavista™ B36X Gas Fireplace...
  • Page 16: Venting Introduction

    Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited. Diagram 8 Regency Bellavista™ B36X Gas Fireplace...
  • Page 17: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency Bellavista™ B36X Gas Fireplace...
  • Page 18: Approved Venting Confi Gurations

    INSTALLATION APPROVED VENTING CONFIGURATIONS HORIZONTAL & VERTICAL TERMINATIONS Regency Bellavista™ B36X Gas Fireplace...
  • Page 19: Approved Venting Configurations

    • Max. 35.5 ft vertical run Vent Reducer • Up to 2 x 90 o elbows • See manual for details Vertical Top Vent Rigid Vent 5" x 8" Not Approved Not Approved This application is NOT approved Not Approved Regency Bellavista™ B36X Gas Fireplace...
  • Page 20: Rigid Pipe Cross Reference Chart

    Offset Support 46DVA-ES (N/A - FPI) 4DT-OS SV4SU Wall Thimble-Black 46DVA-WT 4DT-WT 4DWT 4DWT SV4RSM TE-4DE90 Wall Thimble Support/Ceiling Support 46DVA-DC SV4PF TE-4DE90B Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF Trim Plate-Black 4DT-TP 4DFPB 4DCP SV4LA Regency Bellavista™ B36X Gas Fireplace...
  • Page 21 Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination. Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Bellavista™ B36X Gas Fireplace...
  • Page 22: 5" X 8

    5DWS Offset Support 58DVA-ES - N/A from FPI 5DT-OS Wall Thimble-Black 58DVA-WT 5DT-WT 5DWT TE-5DE90 Wall Thimble Support/Ceiling Support 58DVA-DC TE-5DE90B - N/A from FPI Firestop Spacer 58DVA-FS 5DT-FS 5DFS Trim Plate-Black 58DAV-WFS 5DT-TP 5DCP Regency Bellavista™ B36X Gas Fireplace...
  • Page 23 1 foot of run towards the termination. 36” (914mm) 29-13/16” (757mm) 39-7/16” (1002mm) Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. 48” (1219mm) 38-1/4” (972mm) 47-7/8” (1216mm) Regency Bellavista™ B36X Gas Fireplace...
  • Page 24: Horizontal Terminations

    1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from FPI may be used for Flex installations. Note: If longer runs are required - rigid pipe must be used. Regency Bellavista™ B36X Gas Fireplace...
  • Page 25: Rigid Pipe Venting Arrangements (5" X 8")

    • Max. 3ft. horizontal run The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes.
  • Page 26: Rigid Pipe Venting Systems

    American Metal Products, Security Secure Vent , AmeriVent Direct Vent. AstroCap is the proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Bellavista™ B36X Gas Fireplace...
  • Page 27: Horizontal 5" X 8" Rigid Rear Vent Kit

    Across the face of the unit, wall to wall 75" Vinyl Siding Standoff Inside corner to front face of the unit 37-1/2" (Optional) Astrocap Wall Thimble Pipe Length 45 elbow Rigid Pipe Adaptor 26-1/2” (673mm) Regency Bellavista™ B36X Gas Fireplace...
  • Page 28: Venting Arrangements

    Maximum of four 45 elbows allowed. Note: The Regency Direct Flex Kits (946-515 and 946-516) cannot be used in conjunction with the vent reducer and rigid pipe adaptor. Only rigid pipe may be used when 4" x 6-5/8" is ever used. Horizontal (Feet) 18 18 Restrictor 1”...
  • Page 29: Venting Arrangements Horizontal Termination

    90 elbows 5' Min. 7' Max. is required. 6' Min. 8' Max. 77''7' Vent Restrictor Set at 2" Opening Lengths do not include elbow indicated. Must use reducer # 946-606 and rigid pipe adaptor #770-994. Regency Bellavista™ B36X Gas Fireplace...
  • Page 30: Horizontal Venting With Three (3) 90

    6' Min. 7' Max. 9' Min. required. 7' Min. 8' Max. 10' Min. Vent Restrictor Set at 2" Opening Lengths do not include elbow indicated. Must use reducer # 946-606 and rigid pipe adaptor #770-994 Regency Bellavista™ B36X Gas Fireplace...
  • Page 31: Vertical Termination With Co-Linear Flex System

    fi replaces in this manual. Pipe Length Co-Linear Flex Adapter Reducer #946-606 with Kit# (4 x 6-5/8 venting) 946-563 Rigid Pipe Adapter 90 Degree # 770-994 Elbow Inner Pipe Adapter with Kit# 946-563 Regency Bellavista™ B36X Gas Fireplace...
  • Page 32: Venting Arrangement - Vertical Terminations

    #770-994 Rigid #770-994 Rigid 2” Open Pipe Adaptor Pipe Adaptor Pipe Adaptor Restrictor 2” Open Horizontal Distance (Feet) Horizontal Distance (Feet) Horizontal Distance (Feet) The shaded area in the diagrams show the allowable vertical terminations. Regency Bellavista™ B36X Gas Fireplace...
  • Page 33: Unit Installation With Horizontal Termination

    "Exterior Vent Termination Locations" with each approved venting system, it is section for more details. highly recommended to apply “Mill-Pac” sealant (supplied) to every inner pipe connection. Failure to do so may result Diagram 7 Diagram 1 Regency Bellavista™ B36X Gas Fireplace...
  • Page 34: Unit Installation

    Vinyl Siding 4) Separate the 2 halves of the wall thimble and Wall Thimble securely fasten the one with the tabs to the Screws outside wall making sure that the tabs are Regency Bellavista™ B36X Gas Fireplace...
  • Page 35: Unit Installation With Vertical Termination

    5) Cut a hole in the roof centered on the small locking it. drilled hole placed in the roof in Step 2. The hole should be of suffi cient size to meet the minimum requirements for clearance to combustibles Diagram 4 Regency Bellavista™ B36X Gas Fireplace...
  • Page 36: Pilot Adjustment

    1) Gas on/off knob 2) Manual high/low adjustment 3) Pilot Adjustment 4) Thermocouple Connection - option 5) Outlet Pressure Tap 6) Inlet Pressure Tap 7) Pilot Outlet 8) Main Gas Outlet 9) Alternative TC Connection Point Regency Bellavista™ B36X Gas Fireplace...
  • Page 37: Aeration Adjustment

    Air Temp. Switch Control ground wire Piezo Ignitor (To THTP) Brown Burner ON White White (To TH) Black To Thermocouple IN "S.I.T" Valve (To TH) White ON OFF Remote Receiver Remote Transmitter or Thermostat (Optional) (Millivolt) (Optional) Regency Bellavista™ B36X Gas Fireplace...
  • Page 38: Wiring Diagram For Gtmf Remote

    Ground (To THTP) Brown Burner ON White White (To TH) Black To Thermocouple IN "S.I.T" Valve (To TH) T-Stat ON OFF Remote Receiver Remote Transmitter or Thermostat (Optional) (Millivolt) (Optional) WIRING DIAGRAM FOR GTMF REMOTE Regency Bellavista™ B36X Gas Fireplace...
  • Page 39: Vent Restrictor, Baffl E & Heat Defl Ector Installation

    6) From inside the fi rebox, install the top heat defl ector with 2 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten. Diagram 4 Heat Defl ector Diagram 1 Regency Bellavista™ B36X Gas Fireplace...
  • Page 40: Conversion From Ng To Lp

    Burner Assembly to the left to release it from the orifi ce and lift out. 11) Reinstall new burner orifi ce LPG stamped #55 and tighten. Remove the 2 screws, push Burner Assembly to the left and lift out. Regency Bellavista™ B36X Gas Fireplace...
  • Page 41 17) Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten. Fig.4 WARNING! Do not over tighten the screw. Recommended to grip the wrench by the short side. Regency Bellavista™ B36X Gas Fireplace...
  • Page 42: Dc Sparker Installation

    Wire 26) Connect the DC spark generator wires to the SIT Valve. Secure with a phillips head screw as shown below. Replace with a new 'AA' battery and reinstall battery cover. DC Sparker Generator Wires Regency Bellavista™ B36X Gas Fireplace...
  • Page 43: Brick Panel Installation

    Note: Ensure that an equal space (gap) is maintained on both left panel (see step 5). the right and left side - when installing the back panel. Final Brick Panel Installation Back Panel Installed 8) Reinstall top heat defl ector (reverse Step 3). Regency Bellavista™ B36X Gas Fireplace...
  • Page 44: Optional Panel Installation

    2) Loosen the 2 baffl e screws - position the top panel inside the fi rebox shown in Diagram 4. Slide slots of top panel into position under loosened screws, retighten the screws. Slots on Top Panel Diagram 5 Diagram 3 Regency Bellavista™ B36X Gas Fireplace...
  • Page 45 1) Remove the heat defl ector by removing the 2 screws securing the heat defl ector to the top of the fi rebox (see Diagram 2). Diagram 6 Final Installation Diagram 2 Heat defl ector Regency Bellavista™ B36X Gas Fireplace...
  • Page 46: Log Set Installation

    fi tting into the right side of the grate. 1) Carefully remove the logs from the packaging and unwrap them. The logs are fragile, handle with care - do not force into position. Notch Regency Bellavista™ B36X Gas Fireplace...
  • Page 47 Notch in log F 7) Position Log D across the cutouts in Logs A and B with the notch on the left side of the log fi tting into the 2nd grate tab. 2nd Grate Tab Regency Bellavista™ B36X Gas Fireplace...
  • Page 48 10) Test fi re to ensure proper light off (make sure fl ame fl ows smoothly from one end of the burner to the other). If there is any fl ame hesitation, check that area for any blockage of the burner ports. Notch in log D Regency Bellavista™ B36X Gas Fireplace...
  • Page 49: Optional Wall Thermostat

    (INCLUDED) REMOTE CONTROL 1) Run the supplied 10' of wire through the right Regency offers 3 different remote control or left side gas inlet opening. Be careful not to A wall thermostat may be installed if desired, options which are Profl ame GT, GTM and GTMF damage wire.
  • Page 50 INSTALLATION Regency Bellavista™ B36X Gas Fireplace...
  • Page 51: Fan Installation

    . R e f e r t o w i r i n g d i a g r a m . Electrical Receptacle Push Fan down on mounting pins Diagram 5 Clip Ground Lug Plug fan power cord into rear receptacle Regency Bellavista™ B36X Gas Fireplace...
  • Page 52: Flush Glass Door Installation

    2) Lower the fl ush door, then hook the 2 adjustable tension latches - close the latches to secure the fl ush door(See Diagram 2). Adjustable Tension Latch location Diagram 2 Note: To remove Flush Glass door reverse Steps 1 and 2. Regency Bellavista™ B36X Gas Fireplace...
  • Page 53: Optional Fi Nishing Trim Installation

    3) Hook the tabs up over the brackets to attach. Installation of upper Louver/Flush Panel Tabs on Louver/Flush Panel Installation of lower Bracket on unit for lower Louver/Flush Panel Louver/Flush Panel Bracket on unit for upper Louver/Flush Panel Regency Bellavista™ B36X Gas Fireplace...
  • Page 54: Full Screen Arch Door And Frame Installation

    See Diagram 2 Bracket on unit for bottom mesh door. Diagram 4 7) Install top louver. Diagram 7 a) Locate tabs on top louver Tab on top louver. Diagram 5a Diagram 2 Final Screen Install Regency Bellavista™ B36X Gas Fireplace...
  • Page 55: Operating Instructions

    DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT. 3) Turn the gas control knob to the "OFF" posi- tion to turn off the pilot. Regency Bellavista™ B36X Gas Fireplace Regency Bellavista™ B36X Gas Fireplace Regency Gas Fireplace...
  • Page 56: Copy Of Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS Regency Bellavista™ B36X Gas Fireplace...
  • Page 57: Maintenance Instructions

    Top Louver or Grill. purchase your replacement from an authorized glass properly secured in place. Regency dealer only. Replacement glass (Part # 2) Remove the Trim Kit, Glass Door, Log Set, Grate 940-358/P) is shipped already installed into the 6) Do not use this appliance if any part has been and Burner Assembly (see the "Log Installation"...
  • Page 58: Removing Valve

    Diagram 2: Slide burner assembly to the left and then remove. Diagram 6 7) Remove the 2 screws securing the rear log tray and lift out. Diagram 3 Diagram 3 Diagram 7 Regency Bellavista™ B36X Gas Fireplace Regency Bellavista™ B36X Gas Fireplace...
  • Page 59: Parts List

    Round to Oval Adaptor 13) 556-012 Door Frame 946-001 Oval Duct Adaptor 946-007 Angle Bracket Outerbox Assembly 946-517/P Fan Assembly - Heat Wave Firebox Assembly 946-004 Junction Box 918-759 Manual Not available as a replacement part. Regency Bellavista™ B36X Gas Fireplace...
  • Page 60 PARTS LIST MAIN ASSEMBLY HEAT WAVE DUCT KIT HEAT WAVE DUCT KIT FAN SWITCH ASSEMBLY FAN SWITCH ASSEMBLY Regency Bellavista™ B36X Gas Fireplace Regency Bellavista™ B36X Gas Fireplace...
  • Page 61: Burner Assembly

    556-057 B36X Grate Assembly 910-039 Pilot Assembly - LP 910-386 Thermocouple 904-655 Orifi ce # 45 NG 904-575 Orifi ce # 55 LP 910-341 Thermopile 910-568 Valve NG/LP SIT High/Low 820 Valve Tray - B36X Regency Bellavista™ B36X Gas Fireplace...
  • Page 62 NOTES Regency Bellavista™ B36X Gas Fireplace...
  • Page 63: Warranty

    Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency ®...
  • Page 64 ® Register your Regency warranty online www.regency-fi re.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notifi cation of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

Table of Contents