MUST READ BEFORE
FRAMING
IMPORTANT INFORMATION
Regency City Series San Franciso Bay 50
CB50E-NG / CB50E-LP
FRAMING
DIMENSIONS
SPECIFICATIONS
HEAT RELEASE REQUIREMENTS
QR LINK FOR
PDF DIGITAL COPY
OF SPECIFICATIONS:

Advertisement

loading

Summary of Contents for Regency City Series San Franciso Bay 50

  • Page 1 MUST READ BEFORE FRAMING IMPORTANT INFORMATION Regency City Series San Franciso Bay 50 CB50E-NG / CB50E-LP FRAMING DIMENSIONS SPECIFICATIONS HEAT RELEASE REQUIREMENTS QR LINK FOR PDF DIGITAL COPY OF SPECIFICATIONS:...
  • Page 2 " " 1236mm 288mm dimensions 8" 5" 203mm 127mm Dimensions - Bay Install " " 1236mm 288mm 8" 5" 203mm 127mm " 1551mm " 532mm " " 60" 1524mm 1551mm 519mm " 532mm " 60" 1524mm 519mm " " 423mm 112mm Note: Height Dimension is taken with leveling legs fully inserted and may vary depending on the height of the leveling legs, when unscrewed or extended.
  • Page 3 installation Gas Connection - Bottom of Unit FRONT OF UNIT GAS VALVE 8 " OPENING AT UNIT BASE BACK OF UNIT Gas Connection - Side of Unit | City Series CB50E...
  • Page 4 installation Electrical Connection - Bottom of Unit Electrical Connection - Side of Unit City Series CB50E |...
  • Page 5 dimensions Dimensions - Corner Install " " 1236mm 288mm 8" 5" 203mm 127mm " 1551mm " 532mm " 60" 1524mm 519mm " 101mm " 419mm Note: Height Dimension is taken with leveling legs fully inserted and may vary depending on the height of the leveling legs, when unscrewed or extended. Dimensions will appear as (inches)"...
  • Page 6 Ventilation Openings (Three-sided/Bay Installation) For right/left two-sided corner, see next page. Regency's patented Cool Wall system releases warmth at ceiling level. This system reduces excessive radiant heat in front of the fireplace so you can enjoy your fireplace more often.
  • Page 7 Ventilation Openings (Right/Left Corner) Regency's patented Cool Wall system releases warmth at ceiling level. This system reduces excessive radiant heat in front of the fireplace so you can enjoy your fireplace more often. • Design your own chase vent solution to suit your home •...
  • Page 8 Min 42.25” (1073 mm) installation Chase Enclosure Opening for vent When choosing to install the ventilation openings from the front or both sides, The top of the ventilation opening cannot be any lower than 0-2" (51mm) 4”-4.5” from the top of the chase enclosure for all installations. Minimum height of enclosure from base of appliance is 62-7/8"...
  • Page 9: Installation

    installation Clearances (3-sided) The clearances listed below are minimum distances unless otherwise stated. A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Flue Clearances to Combustibles Clearance Dimension...
  • Page 10 installation Clearances opening opening Floor to ceiling with top opening Full framing with vents in front/2 sides or top opening opening Full framing with low vents in front or 2 sides Full framing with vents in front or 2 sides City Series CB50E |...
  • Page 11 installation Clearances - Corner Install The clearances listed below are minimum distances unless otherwise stated. A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
  • Page 12 installation Mantel Clearances Combustible mantel clearances from top of front facing are shown in the diagram on the right. 1/2" (13 mm) Drywall, wood, wood panel, etc. 12" (305mm) 9” (228 mm) 5 1/4" (133 mm) To Bottom of Top of Fireplace Fireplace Opening...
  • Page 13 installation Framing Dimensions - Bay Install NOTE: Framing may be constructed of combustible material and does not require steel studs. Framing Description CB50E Dimensions 2 x 4: 44-3/4" (1137 mm) Framing Height 2 x 6: 51-7/8" (1318 mm) Framing Width 60'' (1524 mm) Framing Depth 20-7/16"...
  • Page 14 installation Framing Dimensions Corner Kit - Corner Install (Right Corner) NOTE: Framing may be constructed of combustible material and does not require steel studs. Note: A combined minimum of Framing 152 square inches of open area is Description Corner Kit Dimensions required for the convection air outlet to cool the enclosure.
  • Page 15 installation Framing Dimensions Corner Kit - Corner Install (Left Corner) NOTE: Framing may be constructed of combustible material and does not require steel studs. Note: A combined minimum of Framing 152 square inches of open area Description Corner Kit Dimensions is required for the convection air outlet to cool the enclosure.
  • Page 16 installation CB60E CORNER CB60E CORNER INSTALLATION KIT (BLACK) - ASSEMBLY STEPS Corner Installation Kit (Black) - Assembly Steps Inner Firebox Panels Sold Separately Must Purchase Part #686-907 1. Decide on left or right install. Take removable trim off side to be 4. Slide outer side panel down onto the two screws in the firebox body.
  • Page 17 CB60E CORNER installation 10. Install the inner panel for the corner conversion by wedging it into 7. Lift the glass stop and open the glass. the inner lower liner panels. NOTE: The return on the inner panel should be at the top facing inward, and the gasket is facing the side glass. NOTE: The side glass should not be removed.
  • Page 18 CB60E CORNER installation 13. Close the glass, turn the glass lifters to the up position, and lock all 16. Slide the corner panel over to the outer side panel until contact with the upper and lower clamps. magnets is made. 14.
  • Page 19: City Series

    installation CITY SERIES Optional Framing Kit Framing Kit Assembly Tool/hardware required: Additional wall studs required 57-1/4" center to center - Level - Stud Finder 57-1/4" - Cordless Screwdriver - Phillips Bit - 5/16 inch hex head bit - 2" to 3" wood screws (minimum 16) - Flashlight Note: Extra screws are provided to assemble this kit.
  • Page 20 CITY SERIES installation 2. Install the frame assembled in Step 1, onto the back of the unit as 6. Attach the 2 center supports (Part I) to upper- and lower-part B of shown with 2 screws on each side. the back frame with 2 screws each as shown. 7.
  • Page 21 CITY SERIES installation 11. Install 4 horizontal mid braces (Part K) at the top and bottom to 8. Attach 2x Part G to the previously installed Part J parts with 2 screws the Part A. Add the Part K to the Part I and screw them together at each end.
  • Page 22 CITY SERIES installation COMBINED VIEW OF ALL THE PARTS 13. Option 1 (When venting the exhaust at the right end): Install 2 top (Part D) and 2 inner diagonals (Part L) with 2 screws at each end. EXPLODED VIEW OF THE FRAMING KIT 3RD ANGLE TOLERANCES UNLESS FIREPLACE PRODUCTS...
  • Page 23 CITY SERIES installation CV/CB50 CHASE VENT INSTALLATION (WHITE FRONT) Chase Vent Installation (White Front) (Part # 482-991) Framing Opening must be between 3'' (76 mm) and 3.5'' (89 mm) tall, and at least 51-1/2'' (1308 mm) wide to accomodate the Chase vent. Framed opening must be between 3”...
  • Page 24 installation Wall Board/Drywall Installation WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified. Finishing Instructions It is important to follow the framing and finishing instructions to ensure proper placement of fireplace into the surrounding framing/finishing materials. Wall board materials 1/2 in.
  • Page 25 installation Framing and Finishing Inset Installations 1. Frame in the enclosure for the unit with framing material Note : Combustible material may extend a minimum of 1/2" and to a maximum of 5-1/4" (133 mm) from the front top (with larger glass). See Note: When constructing the framed opening ensure there is access to install mantle clearance chart for details.
  • Page 26: Recessed Install

    installation Typical Installations Flush Install Recessed Install SH INSTALL RECESSED INSTALL 152 sq.in MIN. 152 sq.in MIN. CHASE VENT OPENING CHASE VENT OPENING 2X4 OR 2X6 STUD " 133mm MAX. DEPTH MANTLE See Mantel clearance in manual Screws must not MAX DEPTH 36"...
  • Page 27 installation Typical Installations Flush TV with Hearth Maximum TV Recess 152 sq.in MIN. 152 sq.in MIN. CHASE VENT OPENING CHASE VENT OPENING MAX. 2X6 STUD MAX. 2X4 STUD Screws must not penetrate unit Screws must not more than 1/2". penetrate unit Adhere to "No Screw"...
  • Page 28 installation Finishing CV72 Finishing Flush Install Example - Front edge of side liner panels must not be covered by nishing material or - Loosen screws using supplied O set removal of the Firebox Glass will not be Screwdriver and remove bottom and - Finish up to trim on all 4 sides possible side trim pieces...
  • Page 29 installation Wall Board/Drywall Installation WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified. Finishing Instructions It is important to follow the framing and finishing instructions to ensure proper placement of fireplace into the surrounding framing/finishing materials. Wall board materials 1/2 in.