Gas Fireplace MODEL: B36XTCE-10 Medium DV Gas Fireplace Bellavista B36XTCE Video www.regency-fire.com WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Page 2
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The Bellavista™ B36XTCE has been designed to ® provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The Bellavista™ B36XTCE has been approved by Warnock Hersey/Intertek for both safety and efficiency.
MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED ® GAS FIREPLACE HEATERS ANSI Z21.88-2014 / CSA 2.33-2014 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.
table of contents Copy of Safety Decal .............5 Vertical Terminations Three (3) 90 Elbows MA Code - CO Detector..........6 Rigid Pipe 4" x 6 - 5/8" ..........33 Unit Dimensions ............7 Venting Arrangements with Co-Linear Important Message ............8 Flex System ..............34 Before You Start ............8 Co-Linear Flex System Into Masonry Fireplaces ..35 General Safety Information..........8...
This is a copy of the label that accompanies each Bellavista™ B36XTCE Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being ® improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
requirements MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
installation IMPORTANT MESSAGE 4) This appliance must be connected to the YOUNG CHILDREN SHOULD BE CARE- specified vent and termination cap to the outside SAVE THESE of the building envelope. Never vent to another FULLY SUPERVISED WHEN THEY ARE INSTRUCTIONS room or inside a building.
installation INSTALLATION This includes: 4) This appliance is Listed for bedroom installations using the standard Remote CHECKLIST 1) Clocking the appliance to ensure the correct (millivolt thermostat system). Some areas firing rate (rate noted on label 31,000 Btu/h, may have further requirements, check local 1) Locate appliance after burning appliance for 15 minutes.
installation CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. WARNING Caution Requirements Fire hazard is an extreme risk...
installation MANTEL CLEARANCES Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the Diagram on the right. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board. Mantel Clearances B36XTCE From Top of Fireplace...
installation MANTEL LEG CLEARANCES TopView Side opening of fireplace 3.5” 6.5" Allowable mantel leg projection. 12" NON- COMBUSTIBLE REQUIREMENTS: See framing dimensions on next page. NOTE: The 9-1/4" x 40-5/8" non combustible material supplied with this unit can be replaced if trying to achieve a clean finish. A large piece of non combustible material (ie.
installation FRAMING & FINISHING 1. Frame in the enclosure for the unit with framing material. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed. 2. For exterior walls, insulate the enclosure to the same degree as the rest of the house; apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.) WARNING: Failure to insulate and add vapor barriers to the inside of the exterior wall will result in operational and performance problems including, but not limited to: excessive condensation on glass doors, poor flame package, carbon, blue flames etc.
Page 15
installation 7. Non-combustible material (ie. tile, slate, etc) may be brought up to the edge of the glass door of the unit. Minimum clearances must be adhered to, this will assure ease of glass door removal and access to the lower panel. NOTE: Non-combustible finishing materials may be of any thickness desired.
installation UNIT ASSEMBLY PRIOR TO INSTALLATION BEFORE YOU START The Top Nailing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must be correctly positioned and attached before the fireplace is moved into position. TOP STANDOFF ASSEMBLY STANDOFF SLOT LOCATION The top standoffs are shipped in a flat position and must be folded into shape and attached.
installation CONVERSION TO TOP VENT Note: This conversion must be done prior to the unit being placed in position. The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented. Top Collar Assembly Kit Exhaust Assembly Intake Cover Plate...
Page 18
installation 5) From the outside rear of the firebox, remove the intake collar assembly. Remove the 4 - 1/4" x 1/2" screws. See Diagram 5. Diagram 9 Exhaust Assembly Intake Collar Assembly 9) From the outside top of the firebox, install the intake collar assembly. Secure with 4 - 1/4"...
installation VENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATION NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLED PRIOR TO OPTIONAL PANEL INSTALLATION. 1) Determine the venting configuration. 2) Remove top heat deflector and baffle plate (reverse of steps 5 & 6). 3) Go to venting arrangements section (in the manual) to determine if a vent restrictor setting is required.
installation EXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance Requirements Canada Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) Clearance to window or door that may be opened 12"(30cm) 9" (23cm) Clearance to permanently closed window Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) 24"(60cm) 24"(60cm) from the center line of the terminal (check with the local code)
Firestop Spacer 46DVA-FS 4DT-FS 4DFSP 4DFS SV4BF TM-4CS Trim Plate-Black 4DT-TP 4DFPB 4DcP SV4LA TM-4TP Bellavista ® B36XTCE-10 Gas Fireplace Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
Page 22
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com...
FLEX VENT OR RIGID PIPE 5" X 8" The Diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
10) vinyl siding standoff Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency may be used for Flex installations. 3) Regency Direct Vent System (Flex) is only approved for horizontal terminations.
installation HORIZONTAL TERMINATIONS RIGID PIPE 5" X 8" Vinyl Siding Standoff (Optional) Horizontal Termination Wall Thimble Pipe Length Pipe Length Rigid Pipe Adaptor 90 Elbow Rigid Pipe Adaptor Horizontal Termination Top Vent - No Vertical Rise • When venting with a 90° elbow directly off the unit, must use 5"...
installation B36X/XT HORIZONTAL TERMINATIONS ASTROCAP XL & RIGID REAR VENT KIT FOR CORNER INSTALLATIONS HORIZONTAL 5” X 8” RIGID REAR VENT KIT RIGID PIPE 5" X 8" FOR CORNER INSTALLA TIONS Designed for a minimum vent confi guration when using a rear vent application with a horizontal termination in a corner installation.
installation VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" (MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90 two 45 elbows equal one 90 elbow).
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches. Note: The 4" x 6-5/8" Regency Flex Kits (946-515 & 946-516) are not approved for use with this fireplace. Only rigid pipe may be used when 4" x 6-5/8" is used.
installation HORIZONTAL TERMINATIONS TWO (2) 90 ELBOWS (RIGID PIPE 4" X 6 - 5/8") One 90 elbow = Two 45 elbows. Option H + H1 W i t h t h e s e o p t i o n s , 0' Min. 2' Max.
installation VENTING ARRANGEMENTS FOR VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" (MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR) The shaded area in the Diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90 elbows, with Rigid Pipe Venting Systems for Propane and Natural Gas.
installation VERTICAL TERMINATIONS THREE (3) 90 ELBOWS (RIGID PIPE 4" X 6 - 5/8") One 90 elbow = Two 45 elbows. Option H + H1 V + V1 With these options, max. 0' Min. 2' Max. 2' Min. total pipe length is 30 feet 1' Min.
installation VENTING ARRANGEMENTS WITH CO-LINEAR FLEX SYSTEM Masonry chimneys may take various contours which the flexible liner will accommodate. However, THE APPLIANCE MUST NOT BE keep the flexible liner as straight as possible, avoid unnecessary bending. CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL The Air Intake pipe must be attached to the inlet air collar of the termination cap.
installation VERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL & MANUFACTURED HOMES The shaded area in the Diagrams show the allowable vertical terminations. Bellavista ® B36XTCE-10 Gas Fireplace...
installation UNIT INSTALLATION WITH 5) Assemble the desired combination of pipe 7) Ensure that the pipe clearances to and elbows to the appliance adaptor and combustible materials are maintained HORIZONTAL twist-lock for a solid connection. (Diagram 5). Install the termination cap. TERMINATION Note: If installing termination on a vinyl 4"...
installation UNIT INSTALLATION WITH NOTE: Horizontal sections must be sup- ported at intervals not exceeding 3 ASTROCAPXL HORIZONTAL feet (0.9 meter). (Flame picture and DIMENSIONS (946-623/P) TERMINATION performance will be affected by sags in the liner). 5" X 8" VENTING (Flex Vent Systems) 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the...
installation nections are in the fully twist-locked position and sealed. UNIT INSTALLATION WITH VERTICAL 5) Cut a hole in the roof centered on the small TERMINATION 4" X 6-5/8" VENTING (Rigid Vent Systems) Diagram 4 MUST USE REDUCER #946-606 AND RIGID PIPE ADAPTOR Roof Pitch Minimum Vent Height #770-994)
B36XTCE - LP10 System Data ports on the valve. Note: If you have an incorrect flame pattern, contact your Regency dealer for ® For 0 to 4500 feet altitude 1) Make sure the valve is in the "OFF" position. further instructions.
installation B36XTCE/ B36XTE CONVERSION KIT #578-972 FROM NG TO LP for B36XTCE using SIT 885 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Remove the pilot shield by removing 2 Unscrew the pilot orifice with the allen Each Kit contains one LP screws.
B36X/XT installation BRICK PANEL INSTALLATION BRICK PANEL INSTALLATION Dangerous operating conditions may occur if the panels are broken. Handle with care. DO NOT FORCE INTO POSITION. 1) Unwrap the Brick Panels from the protective wrapping. 2) Ensure that the logs are not in the unit. Top Panel Back Panel Left Panel...
B36X / XT installation OPTIONAL BLACK ENAMEL PANEL INSTALLATION BLACK ENAMEL PANEL INSTALLATION Black Enamel Panels • Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. •...
installation B36XT LOG SET INSTALLATION LOG SET INSTALLATION Installation of Optional Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the 2) Spread vermiculite along the base of the fi rebox. logs are broken do not use the unit until they are replaced.
Page 44
B36XT installation 6) Position Log D with the fl at side toward Log E. 5) Place Log A on the front right side of the burner. Position the notch Fit Log D into right peg on Log E. on the bottom right side of the log into the right side of the grate. Slide Log A back towards Log E until the fl...
Page 45
B36XT installation 8) Place the lava rocks on the front of the burner tray in the places shown in the photo. Separate platinum embers and place on the front of the burner tray in and around the lava rocks. Avoid stacking platinum embers. Platinum embers may be placed over burner ports.
installation AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame. Minimum Air Shutter Opening: Note: Any damage due to carboning resulting from improperly setting 1/4"...
B36XTCE / B36XTE installation INSTALLING THE OPTIONAL FAN FAN INSTALLATION Important: 120 Volt AC power is needed 5. Slide the thermodisc/cover assembly into 7. Plug in the fan power cord to the Fan for the blower. The receptacle box will be Control Module into the outlet marked the bracket clip on the underside of the installed on the left hand side of the unit and...
installation WIRING DIAGRAM WITH OPTIONAL FAN SureFire™ Switch Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. 48 | Bellavista ®...
installation OPTIONAL WALL THERMOSTAT INSTALLATION A wall thermostat may be installed if desired. 4) Connect the other thermostat lead to male connector disconnected from Step1using a female spade connector - see picture below. Recommended: The Wall Thermostat should be mounted beside the Re- mote/Unit Receiver which comes standard with the appliance.
installation OPTIONAL LIGHT INSTALLATION OPTIONAL ACCENT LIGHT INSTALLATION B36XT/B36XTE Accent Light Kit # 576-959 7) When light assembly has been fully seated - secure in place with 2 screws that were removed from the Light Assembly -includes cable tie/ gasket. cover plate 910-997 Halogen Bulb...
Page 51
installation 14) Install the halogen bulb supplied with the kit. 11) After the wiring has been connected, secure green ground wire to ground lug as shown below. Important: Use caution - do not touch the bulb during installation. Use the plastic packaging as a protective Ground lug is located on the lower left corner inside the covering while installing the bulb.
Page 52
installation BULB REPLACEMENT 17) Reinstall the logs. 18) Reinstall mesh guard and glass door. 1) Follow steps 1- 4 from previous page. 19) Plug the light assembly into the receptacle located on the 2) Remove 2 screws to remove light diffuser plus gasket. bottom left side of the unit.
Page 53
installation LINE VOLTAGE WIRING TO RECEPTACLE IN UNIT TO MAKE OUTLETS INDEPENDENT OF EACH OTHER Scheme - 1 Using Wall Switch only to turn lights ON/OFF. Ground Optional Lights Break Tab on Black (hot) side Clamp Connector Ground (Copper) 120 V (60 HZ) power Black (Hot) into receptacle White (Neutral)
installation MESH GUARD REMOVAL / INSTALLATION 1. To remove the mesh barrier, grasp mesh barrier on both sides from the bot- 2. When hooks are clear of the bracket–tilt mesh frame out slightly from the tom. Lift up and out slightly to release from bottom magnets and to release bottom and manoeuvre mesh out.
installation FLUSH GLASS DOOR INSTALLATION 1) Line up slots on flush glass door with tabs in firebox. Hook slots on to tabs and lower door slowly (See Diagram 1). Tabs in Firebox Diagram 1 2) Lower the flush door, then hook the 2 adjustable tension latches - close the latches to secure the flush door (See Diagram 2). Adjustable Tension Latch location Diagram 2...
operating instructions OPERATING NORMAL OPERATING INSTRUCTIONS SOUNDS OF GAS APPLIANCES 1) Read and understand these instructions before operating this appliance. It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to 2) Check to see that all wiring is correct and the fact that there are various gauges and types enclosed to prevent possible shock.
operating instructions LIGHTING PROCEDURE IMPORTANT: The remote control system supplied with this appliance has several options for starting/operating the appliance using the power button 3. After approximately 4 seconds the spark ignition system will spark for 60 and ON/OFF key on the hand held transmitter. seconds to light the main burner.
operating instructions COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
In the event that you break your glass by impact, person. covered under warranty. purchase your replacement from an authorized Regency dealer only. Replacement glass (Part 5) The appliance and venting system must be #940-357/P) is shipped already installed into inspected before use, and at least annually, the door frame.
maintenance REMOVING VALVE 8) Disconnect the inlet gas line. 9) Disconnect the EV1, EV2, and ground wires 1) Shut off the gas and electrical supply. from the valve - as shown below. 2) Remove the mesh barrier. 3) Open the flush door and remove the door. 4) Remove the logs.
parts list MAIN ASSEMBLY Part # Description Part # Description 576-084F Top Insulation Plate 578-917 Fan Assembly 576-099 Top Insulation 910-215/P Fan Motor (120 Volts) 556-524 Flue Collar Outer Assembly 911-030 Fan Control Module 556-095 Flue Collar Gasket 911-159 Power Cord (120 Volts) 556-097 Exhaust Gasket 910-142...
Page 62
parts list MAIN ASSEMBLY 62 | Bellavista ® B36XTCE-10 Gas Fireplace...
Conditions: Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at Regency's option, through an accredited distributor or agent provid- ed that the defective part be returned to the distributor or agent Transportation Prepaid, if requested.