Regency Bellavista
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-162
Gas Fireplace
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
B41XTCE
FOR YOUR SAFETY
What to do if you smell gas:
Owners &
Installation Manual
MODELS: B41XTCE-NG
www.regency-fi re.com
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
B41XTCE-LP
06/07/12

Advertisement

Table of Contents
loading

Summary of Contents for Regency Bellavista B41XTCE-NG

  • Page 1 Owners & ™ Regency Bellavista B41XTCE Installation Manual Gas Fireplace MODELS: B41XTCE-NG B41XTCE-LP www.regency-fi re.com WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fi re or explosion may result causing property damage, Do not try to light any appliance personal injury or loss of life.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The Bellavista™ B41XTCE has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The Bellavista™ B41XTCE has been approved by Warnock Hersey/Intertek for both safety and effi...
  • Page 3: Manufactured Mobile Home Requirements

    This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. Ensure that structural members are not cut or weakened during installation. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 4: Table Of Contents

    Three (3) 90 Elbows (Rigid Pipe 5" x 8") ....30 Unit Installation with Horizontal Termination ....31 The Warranty: Limited Lifetime ........71 Unit Installation with Horizontal Termination ....32 Unit installation with Vertical Termination ....33 Gas Line Installation ............33 Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 5: Safety Label

    MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE. 4001172 Minimum Clearances to Combustibles / NATURAL GAS: Model B41XTCE-NG Degagement Minimum De Materiaux Combustibles APPAREIL FONCTIONNANT AU NATURAL GAS CONCU POUR ETRE POELE: Mod le B41XTCE-NG é Ceiling Minimum supply pressure 5.0" WC/C.E.
  • Page 6: Requirements

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 7: Dimensions

    DIMENSIONS UNIT DIMENSIONS 46-11/16" [1185mm] 38-3/8" [974mm] 46-11/16" 26-3/16" [1185mm] [664mm] 7-5/16" [185mm] 35" 3-1/4" [889mm] 38-7/16" [976mm] Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 8: Installation

    4) This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 9: Installation Checklist

    Standard Flush Door e. Remote Control f. Wall Switch g. Wall Thermostat h. Fan Installation (Optional) i. Light Installation (Optional) 7) Final check. Diagram 1 Flat on Wall Flat on Wall Corner Recessed into Wall/Alcove Corner Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 10: Clearances

    Front to Back Wall (Maximum) Notes: 0" No Hearth Required Close to Ceiling Minimum Vent Clearances to Combustibles Horizontal Top 3" (76mm) Horizontal Side 2 " (51mm) Horizontal Bottom 2" (51mm) Vertical Vent 2" (51mm) Alcove Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 11: Mantel Clearances

    12” 7” Non-combustible Header (steel stud) 1" on edge 6” Non-combustible Standoff Inches Top of Fireplace Opening To Floor Mantel Clearances B41XT From Top of 32-11/16" 25-13/16" 22-1/16" 17-9/16" Fireplace Opening (830mm) (656mm) (560mm) (446mm) Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 12: Mantel Leg Clearances

    IN THIS AREA 3-9/16" [91mm] 38-7/16" 976mm 4-1/8" [105mm] NOTE: The 6" x 46-11/16" supplied with the unit is secured directly above the unit as shown above. **All other non-combustible material is supplied by others. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 13: Framing

    ** Important: Framing height requires consideration of the hearth depth. Dimension N = N + the thickness of the installed hearth. Non-Combustible Drywall Header (or other (steel stud) facing) on edge Non-Combustible Header (steel stud) on edge Non-Combustible Facing 11" (279mm) dia. Hole through wall Vent. Opening for gas connection Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 14: Finishing

    NOTE: The 6" x 46-11/16" non combustible material supplied with this unit can be replaced if trying to achieve a clean fi nish. A large piece of non combustible material (ie. 4' x 8' x 1/2" can be used to eliminate taped seams on or near unit. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 15 To maintain a clean fi nished edge - facing material edges may be fi nished with a J-style trim or metal cornerbead (both materials available at your local building or hardware store). IMPORTANT: Materials used must be NON-COMBUSTIBLE. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 16: Unit Assembly Prior To Installation

    Nailing strip for Clean Finish (set fl ush with unit) Nailing strip for Tile Finish (set Nailing strip for back 1/2") Tile Finish (set back 1/2") Nailing strip for Clean Finish (set fl ush with unit) Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 17: Conversion To Top Vent

    2) From inside the fi rebox, remove the baffl e plate by removing 4 screws - remove top front screw fi rst. 6) From the outside top of the fi rebox - slide the square piece of insulation out and discard. Baffl e Plate Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 18 All 4 screws must be used. View Front of Firebox 13) Set vent restrictor accordingly - see next page. 14) From inside the fi rebox, re-install the baffl e plate from step 2. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 19: Venting Introduction

    6) From inside the fi rebox, install the baffl e plate with 4 - 1/4" x 1/2 " AT 1-1/2” screws. Ensure all screws are tightly secure, but do not over tighten. Diagram 1 Baffl e Plate Diagram 3 Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 20: Exterior Vent Termination Requirements

    * Clearance in accordance with local installation codes and the requirements of the gas supplier 3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly 3 feet (91cm) above - if within 10 feet (3m) horizontally Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 21: 5" X 8" Rigid Pipe

    5DWS Offset Support 58DVA-ES - N/A from FPI 5DT-OS Wall Thimble-Black 58DVA-WT 5DT-WT 5DWT TE-5DE90 Wall Thimble Support/Ceiling Support 58DVA-DC TE-5DE90B - N/A from FPI Firestop Spacer 58DVA-FS 5DT-FS 5DFS Trim Plate-Black 58DAV-WFS 5DT-TP 5DCP Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 22 1 foot of run towards the termination. 36” (914mm) 29-13/16” (757mm) 39-7/16” (1002mm) Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard. 48” (1219mm) 38-1/4” (972mm) 47-7/8” (1216mm) Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 23: Venting Arrangements For Horizontal Terminations

    FLEX VENT OR RIGID PIPE 5" X 8" The diagrams show all allowable combinations of vent runs with 5" x 8" venting using the Regency direct vent system or rigid vent system. A vent guard should be used whenever the termination is lower than the specifi ed minimum or as per local codes.
  • Page 24: Horizontal Terminations

    Notes: 1) Liner sections should be continuous without any joints or seams. 2) Only Flex pipe purchased from Regency may be used for Flex installations. 3) Regency Direct Vent System (Flex) is only approved for horizontal terminations.
  • Page 25: Rigid Pipe 5" X 8

    Vinyl Siding Standoff (Optional) Horizontal Termination Pipe Length Wall Thimble Rigid Pipe Adaptor Pipe Length 90 Elbow Rigid Pipe Adaptor IMPORTANT Must use Rear Venting Defl ector packaged with unit in rear vent horizontal termination applications. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 26: Astrocap Xl & Rigid Rear Vent Kit

    90ml MillPac 948-128 3” Vinyl Siding Standoff (Optional) Astrocap 85-3/16” Wall Thimble Pipe Length 45 elbow Rigid Pipe Adaptor IMPORTANT Must use Rear Venting Defl ector packaged with unit in rear vent horizontal termination applications. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 27: Venting Arrangementsfor Horizontal Terminations

    A wall thimble is mandatory for all horizontal terminations due to high temperatures. Horizontal (Feet) 18 18 18 18 Restrictor 1-1/2” Open Set 3 Restrictor 2-1/2” Open Set 2 Restrictor 3-1/2” Open Set 1 47-1/2" (1207mm) Minimum Height Requirement Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 28: Rigid Pipe Venting Systems

    FPI venting systems as well as Simpson Dura-Vent Direct Vent Pro, ICC Excel and Selkirk Direct-Temp. AstroCap XL is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 29: Horizontal Terminations

    6' Min. 5' Max. 11' Min. 8' Max. elbows is required. 7' Min. 6" Max. 12' Min. 9' Max. No Vent Restrictor Installed Lengths do not include elbow indicated. Must use rigid pipe adaptor #770-994. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 30 Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting to 3-1/2" opening, 2-1/2"opening and to 1-1/2" opening. Note: Must use optional fl ue adapter when using Rigid Pipe (Part # 770-994). Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 31: Vertical Terminations

    5' Min. 8' Min. 6' Max. 6' Min. 9' Min. 7' Max. 7' Min 10' Min. 8' Max. No Vent Restrictor Installed Lengths do not include elbow indicated. Must use rigid pipe adaptor #770-994 Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 32: Unit Installation With Horizontal Termination

    4) Level the fi replace and fasten it to the framing using nails or screws through the top and side nailing strips. Diagram 7 Diagram 2 IMPORTANT Diagram 1 Must use Rear Venting Defl ector packaged with unit in rear vent horizontal termination applications. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 33: Unit Installation

    Apply Mill Pac or high temperature silicone to the outer fl ex pipe and slip it over Wall Thimble the outer fl ue collar of the vent terminal at Screws least 1-3/8"(35mm) and fasten with the 3 screws. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 34: Unit Installation With Vertical Termination

    Important: Always check for gas leaks with a vent height may solve the problem. soap and water solution or gas leak detector. Do not use open fl ame for leak testing. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 35: Pilot Adjustment

    886 S.I.T. VALVE DESCRIPTION 1) Manual high/low adjustment 2) Pilot adjustment 3) Outlet Pressure Tap 4) Inlet Pressure Tap 5) Pilot Outlet 6) Main Gas Outlet 7) Main Gas Inlet Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 36: Brick Panel Installation

    fi rebox wall (left side shown). Position the left brick panel in place and secure with the brick panel clip and screw removed from the fi rebox as shown below. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 37: Optional Black Enamel Panel Installation

    fi rebox. See diagram below. panel is centered when installed. Install the right side panel - secure with panel clip and 1 screw. See step 3. Top Panel Bracket Back Panel Right Side Panel Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 38 Top panel bracket shown installed with Stainless Steel Panels 5) Slide top panel under the top of the back and right side panels as shown below. 6) Install left side panel - repeat step 4. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 39: Log Set Installation

    2) Spread vermiculite along the base of the fi rebox. 4) Place Log F on the right side of the burner, directly in front of Log A. Position Log F so it fi ts into the pin on the burner as shown below. Vermiculite Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 40 Position Log G so it fi ts into the pin on the burner as shown below. 10) Slide the right side of Log H back until it touches the tab on the burner shown below. Tab on Burner Back of Log H Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 41 13) Position Log B on top of Log A. Log B fi ts into the pin in Log A. Ensure Log B sits upright 90 degrees with the left side of the log resting on the notch in Log E. See next 2 diagrams. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 42 19) Test fi re to ensure proper lighting (make sure fl ame fl ows smoothly from one end of the burner to the other). If there is any fl ame hesitation, check that area for any blockage of the burner ports. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 43: Optional Fan Installation

    5) Connect the Red wire onto the right side terminal of the fan motor, Connect the red wire into the grommet and push grommet into the fan assembly housing. BLACK 8) Connect and secure fan ground cable to ground lug. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 44 IMPORTANT: edges. These fans collect a lot of dust from within your home. Ensure you maintain these fan motors on a regular basis by vacuuming the fan blades and housing using a soft brush nozzle. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 45: Optional Wall Thermostat

    1) 4 AA batteries must be installed in the battery pack to operate the burner switch. 2) Install 2 AA batteries per side and connect as shown below. The battery pack will be located near the gas controls at the base of the unit. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 46 Note 1 ~ Profl ame Flame Modulator for GTM & GTMF Remote Controls are sold seperately. Choice of NG or LP fl ame modulator (to match unit fuel type). See Regency Retail Price pages for complete details Note 2 ~ FPI Profl ame Remote Controls come standard with white wall mount switch & cover plate.
  • Page 47: Gt Remote Installation

    12) Reverse steps 5 and 4. (green) 13) Match the remote control to the receiver - see remote control instructions. 14) Reverse steps 2 and 1. 15) Check to ensure there are no gas leaks. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 48: Gtm Remote Installation

    4) Remove DFC (digital fi rebox control box) from the fl oor of the unit. 9) Remove the hi/lo knob if installed by removing 2 screws as shown below. 5) Disconnect wire harness, ground wire and spark wire from DFC. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 49 19) Reverse steps 2 and 1. 20) Check to ensure there are no gas leaks. 14) To unattach these wires - un-clip from the wires on the stepper motor side as shown below. Press down this tab Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 50: Gtmf Remote Installation

    9) Remove the hi/lo knob by removing 2 screws as shown below. 6) Disconnect wire harness, ground wire and spark wire from DFC. 10) Install the stepper motor in the same location the hi/lo knob was removed from - with 2 screws as shown below. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 51 18) Plug fan control module into recepticle located on the left hand side of the unit. 19) Match the remote control to the receiver - see remote control instructions. 20) Reverse steps 2 and 1. 21) Check to ensure there are no gas leaks.. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 52: Wiring Diagram

    Air Temp. Switch Control Ground Black Light Switch Switch Ground To Fan (see above) Do Not Break Tab Break Tab Optional Accent Light on Neutral (silver terminals) Copper terminals Black Green Receptacle in Unit Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 53: Profl Ame System Wiring Diagram

    SureFire™ Switch GT, GTM, GTMF Option PROFLAME REMOTE SERIES 946-690 GT Remote System 946-691* GTM Remote System 946-692* GTMF Remote * Must also order a 946-693-NG or 946-694 modulator if using the noted remote controls. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 54: Optional Accent Light Installation

    fi rebox base. Left side shown, repeat for right side. Diagram 2: Slide burner assembly to the right and then remove. 8) Remove the 2 screws securing the rear log tray and lift out. Diagram 3 Diagram 3 Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 55 14) Install a bulb into each light assembly. Note: Glass is longer than diffuser for ease of removal. Note: Oils from hands will shorten the life of the bulbs, do not handle bulbs with bare hands. 19) Reverse steps 9 - 1. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 56: Mesh Guard Installation

    1) Hook mesh guard frame over top of fl ush glass door frame as shown in Diagram 1. Push bottom part of mesh frame over fl ush glass door frame until tabs snaps into place. 2) Install mesh guard and fl ush glass together - following fl ush glass door installation instructions. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 57: Flush Glass Door Installation

    Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See Diagram 3. Diagram 3 To remove the fl ush door, reverse the above steps. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 58: Operating Instructions

    Listed below are some examples. OFF switch or press ON/OFF button if using All are normal operating sounds and should optional remote. not be considered as defects in your appliance. c) Repeat step 2. Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 59: Copy Of Lighting Plate Instructions

    If service is to be performed - you must disconnect power to the unit, from the battery pack, refer to manual. Appuyez sur le bouton ON / OFF Si le service est effectuée, vous devez débrancher l'appareil, du bloc-piles, voir le manuel d'instruction pour plus de détails. DO NOT REMOVE THIS INSTRUCTION PLATE 918-628b Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 60: Maintenance

    In the event that you break your glass by impact, air is not obstructed. purchase your replacement from an authorized Regency dealer only. Replacement glass (Part Note: Never operate the appliance without #940-362/P) is shipped already installed into the glass properly secured in place.
  • Page 61: Accent Light Bulb Replacement

    Diagram 2: Slide burner assembly to the right and then remove. 11) Reverse steps 9 - 1. 8) Remove the 2 screws securing the rear log tray and lift out. Diagram 3 Diagram 3 Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 62: Valve Replacement

    Diagram 3 Diagram 3 11) Remove the 14 screws securing the valve tray assembly in place (Diagram 7) and then lift the entire assembly out Also remove the valve gasket. Diagram 7 Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 63: Parts List

    Optional Accent Light Outerbox Assembly Firebox Assembly 919-162 Manual 506-917 Fan Assembly 910-215/P Fan Motor (120 Volts) * Not available as a replacement part. 432-966 Fan Switch Assy (120 Volts) 910-813 Power Cord (120 Volts) Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 64: Burner Assembly

    Valve Shield Valve Mounting 506-930 Log Set 506-055 Valve Tray Plate 10) 506-075 Air Defl ector 11) 380-013 Pilot Holder Extruded 12) 911-006 Pilot Assembly - NG 911-007 Pilot Assembly - LP Flame Sensor Igniter Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 65 NOTES Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 66 NOTES Regency Bellavista™ B41XTCE Gas Fireplace...
  • Page 67: Warranty

    Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
  • Page 68 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Regency Bellavista, AstroCap and SureFire™are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2012, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for: