Honeywell TH8320R1003 Installation Manual page 38

Visionpro 8000 with redlink
Hide thumbs Also See for TH8320R1003:
Table of Contents

Advertisement

®
VISIONPRO
8000 WITH REDLINK™
ISU
Installer Setup
Number
Name
407
Min. Cool
Off
Recovery Ramp
1° F/hr to 20° F/hr
Rate
407
Min. Cool
Off
Recovery Outdoor
-20° F to 100° F
Temp
68-0312—03
Table 2. Installer Setup (ISU) Table. (Continued)
Settings
Default
3° F/hr
90° F
38
Residential,
Commercial
Requires
or Both
EIM
Commercial
No
Off: The cooling system will begin recovery at
the time that is scheduled.
When a Minimum Recovery Ramp Rate is
set, the thermostat will begin recovery early to
ensure the temperature is reached at the
scheduled time.
Set a Minimum Recovery Ramp Rate based
on the rate that the cooling system can
recover at for a hot day in your region. Default
setting is 3° F / hour.
If an outdoor sensor is installed, set an
Outdoor Temperature that is representative of
a hot day in your region to be associated with
the Minimum Recovery Ramp Rate. The
thermostat will begin recovery at the optimal
time based on a calculated ramp rate, allowing
the system to recover on time and save
energy during changing outdoor conditions.
During recovery, the setpoint changes at a
rate in degrees per hour depending on the
outdoor temperature. If there is no outdoor
sensor, the Minimum Recovery Ramp Rate is
used.
Commercial
No
Off: The cooling system will begin recovery at
the time that is scheduled.
When a Minimum Recovery Ramp Rate is
set, the thermostat will begin recovery early to
ensure the temperature is reached at the
scheduled time.
Set a Minimum Recovery Ramp Rate based
on the rate that the cooling system can
recover at for a hot day in your region. Default
setting is 3° F / hour.
If an outdoor sensor is installed, set an
Outdoor Temperature that is representative of
a hot day in your region to be associated with
the Minimum Recovery Ramp Rate. The
thermostat will begin recovery at the optimal
time based on a calculated ramp rate, allowing
the system to recover on time and save
energy during changing outdoor conditions.
During recovery, the setpoint changes at a
rate in degrees per hour depending on the
outdoor temperature. If there is no outdoor
sensor, the Minimum Recovery Ramp Rate is
used.
Notes