8000 WITH REDLINK™
7. Set the desired lockout option. See Fig. 183.
NOTE: ISU 1014 gives the option to lockout ventilation
during calls for humidification. This helps main-
tain the desired humidity level.

Control Humidification Level

1. Touch MENU and select Humidification.
Humidification
Window Protection
68-0312—03
Fig. 182.
Fig. 183.
MCR34100
Fig. 184.
MCR34128
Fig. 185.
2. Select Auto.
Humidification
3. Touch
or
to select humidity level.
4. Touch Done to save your settings. Touch Cancel to
ignore changes.
5. If frost or condensation appears on the windows, press
MENU, scroll down and select Window Protection.
6. Window Protection is set on a scale from 1–10. A setting
of 1 represents poorly insulated windows and a setting of
10 represents well insulated windows. A lower number
automatically reduces the humidity to help prevent frost
or condensation on your windows. Use a higher number
if indoor air seems too dry. To prevent frost/condensation
on your windows during cold outdoor temperatures,
poorly insulated windows require a lower Window Pro-
tection setting, which will limit how much your humidifier
can run.
7. After you set the Window Protection setting, check for
frost/condensation on your windows in the morning. If
frost/condensation is present, adjust the Window Protec-
tion setting to the next lowest number and check for frost/
condensation on your windows the next morning. Con-
tinue to adjust the Window Protection setting to a lower
number until frost/condensation is no longer present.
NOTE: The Window Protection option is only available if
an optional outdoor sensor is installed.
NOTE: If humidification and dehumidification are setup
to operate in the same system mode (Heat, Cool,
Off) and you are sensing humidity from one loca-
tion, the thermostat will automatically enforce a
15% deadband between the humidification and
dehumidification settings. The thermostat will
automatically switch between humidification and
dehumidification to maintain the desired humidity
level.