Back Feed Fine Adjustment (Back Adj.); X-Coordinate Fine Adjustment (X Adjust.) - Toshiba B-SX4 Series Key Operations Manual

Hide thumbs Also See for B-SX4 Series:
Table of Contents

Advertisement

(3) Back feed fine adjustment (BACK ADJ.)

+9.5 mm
+9.0 mm
+0.5 mm
RESTART
+0.0 mm
-0.5 mm
FEED
-9.0 mm
-9.5 mm
NOTE:
There may be cases where a label is not returned to the home position depending
on the print conditions, even if a backfeed, of which the length is the same as the
forward feed, is performed. In issues where any paper sensor is used, if the label
pitch length is almost the same as the distance between the thermal print head and
the paper sensors (75.5 mm), a label/tag may not be returned to the home position
when operations with a backfeed (such as cut issues, strip issues, automatic
forward feed standby) are performed. It may result in an error. In such cases, to
prevent an error from occurring, the backfeed length should be increased by
performing the back feed fine adjustment in the + direction.

(4) X-coordinate fine adjustment (X ADJUST.)

+99.5 mm
+99.0 mm
+0.5 mm
RESTART
+0.0 mm
-0.5 mm
FEED
-99.0 mm
-99.5 mm
+0.0 mm
+3.0 mm
-3.0 mm
Paper feed direction
- 83 -
Print start position
(Home position after a back feed)
Print start position
(Home position after a back feed)
Print start position
(Home position after a back feed)
XYZ
-
+