(5) Print density fine adjustment (Thermal transfer/direct thermal) (TONE ADJ.)
+10 step
+9 step
RESTART
+1 step
+0 step
-1 step
FEED
-9 step
-10 step
(6) Ribbon motor drive voltage fine adjustment setting (Rewind) (RBN ADJ <FW>)
[RESTART]
RBN ADJ <BK> +0
[RESTART]
RBN ADJ <BK> -1
[RESTART]
RBN ADJ <BK> -14
[RESTART]
RBN ADJ <BK> -15
(7) Ribbon motor drive voltage fine adjustment setting (Back tension) (RBN ADJ <BK>)
[RESTART]
RBN ADJ <BK> +0
[RESTART]
RBN ADJ <BK> -1
[RESTART]
RBN ADJ <BK> -14
[RESTART]
RBN ADJ <BK> -15
Darker
Standard
Lighter
+0 step (Standard)
[FEED]
-1 step (5% × -1 = -5%)
[FEED]
-14 step (5% × -14 = -70%)
[FEED]
-15 step (5% × -15 = -75%)
[FEED]
• 1 step = 5%
+0 step (Standard)
[FEED]
-1 step (5% × -1 = -5%)
[FEED]
-14 step (5% × -14 = -70%)
[FEED]
-15 step (5% × -15 = -75%)
[FEED]
• 1 step = 5%
- 84 -