(26) Plug-and-play operation setting (PLUG & PLAY)
RESTART
FEED

(27) Label end/ribbon end process setting (LBL/RBN END)

RESTART
FEED
• TYP1: When a label end or ribbon end is detected in the middle of printing, printing is
immediately stopped.
performed, and then the printer starts printing from the unfinished label.
• TYP2: TYPE 2 is available only when the ribbon saving function is set to OFF. If the ON
(LBL) or ON (TAG) is selected, TYPE 1 will be automatically performed regardless
of the selection.

[Label end]

When a label end is detected in the middle of printing, the printer completes the
half-finished label and stops when the next label is at the home position,
displaying the error message "NO PAPER
number of labels.) The remaining number of labels = [Specified number of
labels] − [The number of finished labels including half-finished one]
If a label end is detected while the specified last label is printed, the position of
"X" will be blank.
When the printing is restarted, first the initial feed is performed, and then the
printer starts printing from the next label. In case of the label end while the
specified last label is printed, only the initial feed is performed, and if the status
response is set to ON, an issue end status is sent following a feed end status.

[Ribbon end]

When a ribbon end is detected when the unfinished label length is 30 mm or
more, printer prints for 20 mm and stops printing, displaying an error message
"NO RIBBON
The remaining number labels = [Specified number of labels] − [The number of
finished labels] − 1
If a ribbon end is detected while the specified last label is printed, the position of
"X" will be blank.
When the printing is restarted, first the initial feed is performed, and then the
printer starts printing from the next label. In case of the ribbon end while the
specified last label is printed, only the initial feed is performed.
• OFF: Plug-and-play operation is disabled.
• ON: Plug-and-play operation is enabled.
NOTE:
In the USB interface, plug-and-play operation is always
enabled, regardless of this setting.
• TYP1:
When a label end or ribbon end state is detected, the printer
stops even if it is printing.
• TYP2:
When a label end or ribbon end state is detected, the printer
prints the current label as far as possible, then stops.
When the printing is restarted, first the initial feed is
X". ("X" indicates the remaining number of labels.)
- 70 -
X". ("X" indicates the remaining

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B-sx5 series

Table of Contents