6.11.2 Setting Contents

(1) RFID read test

RESTART
FEED
OFF: A read test is not performed.
ON: The printer enters the read test mode, and a read test is performed each time the
[PAUSE] key is pressed. The read data on the tag is displayed on the LCD message
display. If the tag cannot be read, "RFID TIMEOUT" or "RFID READ ERROR" is
displayed. Only the tags selected by the RFID tag type selection can be read. An
RFID tag read error will result if the type of the tag to be read and the type of the tag
selected by the RFID tag type selection do not match. Make sure the RFID tag type
has been selected before the read test is started.
LCD can display up to 16 digits x 2 lines data. (See below.)
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6
6 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1
The data, displayed in hex. numbers, is an EPC code in the EPC area. (Only when the B-
SX704-RFID-U2 is used.) When the RFID tag contains data of 16 digits or more, the first
16 digits are displayed. When data volume is less than 16 digits, the vacant digits will be
filled with spaces.

(2) RFID carrier sense setting

RESTART
FEED
OFF: A carrier sense is not performed.
ON: The printer enters the carrier sense mode, and performs a carrier sense.
seconds, environmental radio wave of each channel is picked up for about 30 times
(Enabled only when the B-SX704-RFID-U2 is used.)
LCD display example
1 : 1 0 0 %
2 :
The left-most number indicates a channel number, and a percentage means the availability
of the channel which is determined by performing approx. 30 carrier senses. Thus, "100%"
means that this channel is not used by any other devices. The display can be scrolled up
or down, from Channel 1 (1CH) to channel 9 (9CH), by using the [FEED] or [RESTART] key.
Pressing the [PAUSE] key causes the printer to perform a carrier sense again. To quit a
carrier sense, press the [FEED] and [RESTART] keys at the same time.
"MAX 0011" means the value of the maximum radio wave picked up.
• OFF:
A read test is not performed.
• ON:
A read test is performed.
• OFF:
A carrier sense is not performed.
• ON:
A carrier sense is performed.