599447A

8.20 Mains Filter Cover and PCB Mains Filter

8.20.1 Remove lower tub (refer Section 8.5)
8.20.2 Release the clips on the mains filter cover and lift it off.
8.20.3 Disconnect all wiring to the PCB mains filter.
8.20.4 Remove the earth screw through the wire and the mains filter housing
to the chassis.
8.20.5 Use a screwdriver to release the clips holding the circuit board inside
the housing and lift it out.
8.20.6 Refit in reverse manner.

8.21 Water Inlet Valve

8.21.1 Remove the lower tub (refer Section 8.5).
8.21.2 Remove the mains filter cover (refer Section 8.20).
8.21.3 Partially lift the inlet valve up out of the housing.
8.21.4 Disconnect the inlet hose connection.
Caution; - water will drip
8.21.5 You can now slide the water valve up out of the housing.
8.21.6 Remove the connectors.
8.21.7 Mark which hose goes to the top on a double product.
8.21.8 Undo the black clips by pushing the ends apart sideways.
8.21.9 Remove the fill hoses.
8.21.10 Refit in reverse manner.