Slide Rail Replacement; Mains Filter Cover And Pcb Mains Filter - Fisher & Paykel DishDrawer DD24D Series Service Manual

Hide thumbs Also See for DishDrawer DD24D Series:
Table of Contents

Advertisement

599735A
8.22

Slide Rail Replacement

1.
Remove the lid actuator from the slide rail (refer to
Section 8.22).
2.
Bottom slide rails only. Remove the lower chassis
trim (refer to Section 8.27) to gain access to the
screws. Remove the two hex drive screws securing
the slide mounting bracket at the front.
3.
Tap the slide rails from underneath at the front. This
will knock the slide rail up and free from its location in
the chassis.
4.
The slide runner may now be pulled forward to
release it from its location in the rear of the chassis.
Refit in reverse manner.
Take care to ensure the chassis is square before
tightening these screw.
8.23

Mains Filter Cover and PCB Mains Filter

1.
Remove lower tub (refer to Section 8.6)
2.
Release the clips on the mains filter cover and lift it
off.
3.
Disconnect all wiring to the PCB mains filter.
4.
Remove the earth screw through the wire and the
mains filter housing to the chassis.
5.
Use a screwdriver to release the clips holding the
circuit board inside the housing and lift it out.
Refit in reverse manner.