LIGHTING AND SHUTDOWN.

NOTE: Prior to lighting, check all fittings for leakage. This is accomplished by applying soapy water on all
connections made. If there is any leakage, bubbles will appear at the point of connection. If bubbles occur,
tighten the fittings until the bubbles no longer appear.
IMPORTANT: TEST ALL CONNECTIONS WHETHER FIELD OR FACTORY MADE.
NOTE: The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of ½ psig (3.5 kPa).
NOTE: The appliance must be isolated from the gas supply piping system by closing its equiipment shut off valve during any
pressure testing of the gas line at test pressures equal to or less than ½ psig (3.5 kPa).
Pressure check taps for the manifold (outgoing) and inlet (incoming) pressures are located in front of the gas valve. The right
pressure tap is the manifold pressure and the left pressure tap is the incoming pressure. Follow instructions on page #20 for
checking these pressures.
WARNING:
If you do not follow these instructions exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A.
This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING, smell all around the appliance for gas.
Be sure to smell next to the floor because some gas is
heavier that air and will settle on the floor.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in, or turn by
hand, don't try to repair it, call a qualified service
technician. Forced or attempted repair may result in a fire
or explosion, and loss of warranty.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
which has been under water.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
NOTE: Read 1-8 before lighting the unit for the first time. Refer to the Figure 16 on page #19.
1.
Set the thermostat to the lowest setting, if installed.
2.
Turn off all electric power to the appliance. (Fan)
3.
Lift up the panel under the fireplace to access the gas valve & controls. Push the panel 'in' slightly and it will stay
in position.
4.
Push in control knob (A) slightly and turn clockwise
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
5.
Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow the safety information listed above.
If you don't smell gas, go to the next step.
6.
Find the pilot - follow metal tube from gas control. The pilot is located inside
the combustion chamber.
7.
Turn the control knob (A) on gas valve counterclockwise
FOR YOUR SAFETY - READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
DUE TO HIGH SURFACE TEMPERATURES, KEEP
CHILDREN, CLOTHING AND FURNITURE AWAY
This appliance needs fresh air for safe operation and
must be installed so there are provisions for
adequate combustion and ventilation air.
WHAT TO DO IF YOU SMELL GAS:
*Do not touch electrical switches.
*Do not try to light any appliance.
*Do not use any phone in your building.
*Follow the gas supplier's instructions
*Immediately call your gas supplier from a
neighbor's phone.
*If you cannot reach your gas supplier, call the fire
department.
to "OFF".
to "PILOT".