COMPLETE THE INSTALLATION

1.
THIS STEP SHOULD ONLY BE DONE BY A QUALIFIED INSTALLER OR SERVICE TECHNICIAN
Perform lighting and shutdown procedures as described on pages #18-#19. This should be done prior to
replacing the glass so that any necessary adjustments can be made and proper operation verified.
2.
SEASONAL HEAT DUMP:
This fireplace has been manufactured with an adjustable heat dump outlet inside the firebox (at the top).
This will allow infinite control over the amount of heat emitted into the living area without affecting the
flame.
CAUTION: IF THE FIREPLACE HAS BEEN IN OPERATION, ALLOW AMPLE TIME FOR IT TO
ATTENTION INSTALLER:
TO ADJUST:
Remove the cast iron door assembly & glass assembly, open or close the damper as
desired, then re-install the glass assembly & cast iron door assembly.
Figure 15
HEAT OUTLET SHOWN
IN CLOSED POSITION.
3.
Re-install the glass & cast iron door assembly. Refer also to page #11.
A) Align the slots in the top of the glass assembly over the tabs on the fireplace.
B) Place the glass assembly so it is flush with the front of the fireplace front.
C) Pull the knobs on the latch bar first out, then up and release.
D) The glass assembly is now secured.
E) Align the mounting brackets on the back side of the cast iron door assembly onto the mounting rod
at the top of the fireplace and set down into position. The door assembly should set between the
side frames.
WARNING: DO NOT OPERATE THIS FIREPLACE WITH THE GLASS ASSEMBLY
REMOVED, CRACKED OR BROKEN. Replacement of the glass assembly, PART
#70011T (glass with gasket), should be done by a licensed or qualified service
person.
COOL BEFORE ADJUSTING THE HEAT OUTLET OPENING OR USE THE
APPROPRIATE PROTECTION TO PREVENT SERIOUS BURNS.
Please install the fireplace with this heat vent damper in the closed position.
HEAT OUTLET SHOWN
IN PARTIAL OPENED POSITION.