Trouble Shooting Guide - kozy heat 55801 Duluth Installation & Operating Manual

Free-standing direct vent fireplace
Table of Contents

Advertisement

TROUBLE SHOOTING GUIDE

NOTE: The regulator board includes the following items: Regulator, generator, pilot, piezo, electrode,
rocker switch, burner, orifice and orifice holder.
dealer for the appropriate repair / replacement procedures to follow.
WARNING: DO NOT ATTEMPT TO SERVICE THIS UNIT IF YOU ARE NOT A QUALIFIED INSTALLER OR
REPAIRMAN.
1. If the fireplace fails to ignite, a qualified service person should check the unit installation.
2. It is imperative that the control compartment, burner and circulation air passageways of the unit
be kept clean. This is necessary to provide adequate combustion and ventilation air.
3. All of the working parts of this fireplace can be removed at one time. Before removing regulator
board, check for loose wires.
PROBLEM
1. No spark when piezo
button is depressed.
2. Pilot won't light.
Figure 18
If any of these items are defective, contact your
CAUSE
Wire on back of piezo button
is loose or off.
Wire from piezo to electrode is
loose at electrode.
Electrode moved out of position.
Gas shut 'OFF'.
Gas line not purged.
Gas line not bled out.
No spark at piezo.
Page 22
SOLUTION
Put wire back into place.
Reconnect wire.
Realign electrode with 1/8" space
between it and pilot.
Turn gas 'ON'.
Must
be purged by qualified
service technician.
Hold black control knob in long
enough to bleed out line.
See problem #1.
ON/OFF ROCKER SWITCH LOCATED
IN LOWER RIGHT FRAME ON FIREPLACE.