Ip Fax Switches - Ricoh D069 Field Service Manual

Hide thumbs Also See for D069:
Table of Contents

Advertisement

Set CNG send time interval
Some machines on the receiving side may not be able to automatically switch the 3-second CNG
interval.
0-7
High order bit
Low order bit
G3 Switch 0F [SP No. 1-105-016]
No
FUNCTION
Alarm when an error occurred in
Phase C or later
0
0: Disabled
1: Enabled
Alarm when the handset is off-hook
at the end of communication
1
0: Disabled
1: Enabled
2-3 Not used
Sidaa manual calibration setting
4
0: Off
1: On
5-6 Not used

IP Fax Switches

IP Fax Switch 00 [SP No. 1-111-001]
No.
FUNCTION
0
Not used
3000-2250ms: 3000-50xNms
3000 – 50 x Nms 0F (3000 ms) ≤ N ≤ FF (2250 ms)
00-0E(3000-3700ms: 3000+50xNms
3000 – 50 x Nms 0F (3000 ms) ≤ N ≤ 0F (3700 ms)
COMMENTS
If the customer wants to hear an alarm after each error
communication, change this bit to "1".
If the customer wants to hear an alarm if the handset is off-
hook at the end of fax communication, change this bit to
"1".
Do not change the settings.
1: manually calibrates for communication with a line,
whose current change occurs such as an optical fiber line.
Do not change the settings.
Do not change this setting.
Bit Switches
COMMENTS
7
279

Advertisement

Table of Contents
loading

This manual is also suitable for:

D068D067D072

Table of Contents