5. Appendix: SP Mode Tables
Input Check (SP5-803)
Conducting Input Check
1. Select SP5-803.
2. Select the number (see the table below) corresponding to the component.
3. Select "Execute." The copy mode is activated.
4. The sign "01H" or "00H" is displayed (see the table below).
Input Check Table
Num.
5
001
Safety SW
003
Right Cover SW
006
Upper Relay S
007
Lower Relay S
009
Regist Sensor
010
Exit Sensor
011
Duplex Inverter S
014
By-pass PE S
016
Upper PE S
017
BK-Upper PE S
020
BK-Lower PE S
027
PCU Set Signal
028
BK type
030
Duplex Installed
032
Main M Lock
033
Polygon M Lock
035
Total CO Install
200
Sensor/Switch
1h
Open
Open
Paper detected
Paper detected
Paper detected
Paper detected
Paper detected
Paper detected
Paper detected
Paper detected
Paper detected
Installed
*
Installed
Locked
Locked
Installed
0h
Closed
Closed
Not detected
Not detected
Not detected
Not detected
Not detected
Not detected
Not detected
Not detected
Not detected
Not installed
*
Not installed
Not locked
Not locked
Not installed