3. Appendix: Service Call Conditions
No.
Definition
982
B
3
984
B

GW SC Code Descriptions

SC6xx
No.
Definition
632
C
633
C
32
Symptom
Localization error
The localization information in the
nonvolatile ROM and in the NVRAM is
different (
SP5-807-001).
Print image transfer error
Print images are not transferred.
Symptom
MF accounting device error 1
The machine sends a data frame. → No
normal end signal returns. → This
symptom happens three times.
MF accounting device error 2
The machine is communicating with the
accounting device. → The break signal
returns.
Possible Cause
• Localization setting not specified (The
main power switch is turned on for the
first time after the NVRAM is
replaced.)
• Incorrect localization setting
• Defective NVRAM
• Defective controller
• Defective BICU
• Loose connection between the
controller and the BICU
Possible Cause/Countermeasure
• Defective or broken line between
machine and device
• Defective or broken line between
machine and device