7. Appendix: Fax Service Program (Only For D068/D069)
CCM connection
3
0: No CCM connection
1: CCM connection
Message reception selection from non-
registered SIP server
4
0: Answer
1: Not answer
ECM communication setting
5
0: No limit for image compression
1: Limit for image compression
6-7
Not used
IP Fax Switch 03 [SP No. 1-111-004]
7
No.
Effective field limitation for G3 standard
function information
0
0: OFF, 1: 4byte (DIS)
Switching between G3 standard and
G3 non standard
1
0: Enable switching
1: G3 standard only
2
Not used.
ECM frame size selection at transmitting
3
0: 256byte, 1: 64byte
DIS detection times for echo prevention
4
0: 1 time, 1: 2 times
282
FUNCTION
When "1" is selected, only the connection call
message with H.323 or no tunneled H.245 is
transmitted via CCM.
0: This answers the INVITE message from the SIP
server not registered for the machine.
1: This does not receive the INVITE message from the
SIP server not registered for the machine and send a
refusal message.
0: This does not limit the type of the image
compression with ECM communication.
1: When the other end machine is Ciscco, this permits
the image compression other than JBIG or MMR with
ECM communication.
Do not change these settings.
COMMENTS
Limits the effective field for standard G3 function
information.
Enables/disables switching between G3 standard
and G3 non-standard.
Do not change this setting.
Selects the ECM frame size for sending.
Sets the number of times for DIS to detect echoes.