2. Installation

Installation Requirements

Environment

–Temperature and Humidity Chart–
2
• Temperature Range: 10°C to 32°C (50°F to 89.6°F)
• Humidity Range: 15% to 80% RH
• Ambient Illumination: Less than 1,500 lux (Do not expose to direct sunlight.)
• Ventilation: Room air should turn over at least 3 times/hr/person
• Ambient Dust: Less than 0.1 mg/m
• Do not install the machine where it will be exposed to direct sunlight or to direct airflow (from a fan,
air conditioner, air cleaner, etc.).
• Do not install the machine where it will be exposed to corrosive gas.
• Place the machine on a firm and level base.
• Do not install the machine where it may be subjected to strong vibration.

Machine Level

Front to back:
26
3
Within 5 mm (0.2") of level