Flaperon Mix; Step #36 Flap Rate, Camber Mix And Camber Adjust - JR X9303 2.4 Instruction And Programming Manual

9-channel computer radio system with spektrum 2.4ghz dsm technology
Hide thumbs Also See for X9303 2.4:
Table of Contents

Advertisement

Step #36 Flap Rate, Camber Mix and Camber Adjust

A few pilots prefer to have variable camber adjustment
during launch. This enables last minute adjustments to be
made based on wind and winch conditions.
Important: The flaperon and elevator values in the
camber mix menu are based on a percentage of the
programmed flap rate. The flap rates are defaulted
to 0% from the factory, so flaperon and elevator mix
values have no effect until the flap rate values are
set. Because of this, it's mandatory to first adjust the
flap rates before adjusting the flaperon and elevator
camber mixes. Also remember that changing the
flap rate values also affects the flaperon and elevator
camber mix.

Flaperon Mix

Note: Flap rate must be set before camber mix.
In
rotate the Selector until
FUNC.LIST
highlighted. Press the Selector to access the Camber
Mix menu. Rotate the Selector to highlight the land
down value then press the Selector to access
FPRN
this value. With the flight mode switch in the lower LAND
mode, move the left side lever to the lowest position and
[Flaprn MX] ◊U
CRUISE
LAUNCH
LAND
is
Flaprn MX
[Flaprn MX] ◊U
CRUISE
LAUNCH
LAND
Flaperon Mix
In
rotate the Selector until
FUNC.LIST
highlighted. Press the Selector to access the Flap Rate
menu. Rotate the Selector to highlight the land down
value then press the Selector to access this value. With
the flight mode switch in the lower position mode, move
the left side lever to the lowest position and adjust the
down value to the desired flap position. Now with the
flight mode switch in the lower land mode, move the left
side lever to the uppermost position and adjust the up
value to the desired flap position. Press the LIST button
to return to the Function Mode screen.
UP
DN
0%
0%
0%
0%
0%
0%
adjust the down value to the desired flaperon position.
Press the Selector to store the value. Now with the flight
mode switch in the lower land mode, move the left side
lever to the uppermost position and adjust the up value
to the desired flaperon position and store by pressing
the Selector. Repeat the process for the up and down
elevator camber mix. Press the LIST button to return to
the Function Mode screen.
UP
DN
0%
0%
0%
0%
0%
0%
is
Flaprn MX
S-65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents