count
byte
order
fragments
log
threshold-in
msgs count
interval
minutes
monitor
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is five minutes. By default,
flow-based monitoring is not enabled.
Command
CONFIGURATION-IP ACCESS-LIST-STANDARD
Modes
Command
Version 9.4(0.0)
History
Version 9.3(0.0)
Version 8.3.16.1
Access Control Lists (ACL)
the message type. The range is 0 to 255 for ICMP type and 0
to 255 for ICMP code.
(OPTIONAL) Enter the keyword count to count packets the
filter processes.
(OPTIONAL) Enter the keyword byte to count bytes the filter
processes.
(OPTIONAL) Enter the keyword order to specify the QoS
priority for the ACL entry. The range is 0 to 254 (where 0 is
the highest priority and 254 is the lowest; lower-order
numbers have a higher priority). If you do not use the
keyword order, the ACLs have the lowest order by default
(255).
Enter the keyword fragments to use ACLs to control packet
fragments.
(OPTIONAL) Enter the keyword log to enable the triggering
of ACL log messages.
(OPTIONAL) Enter the threshold-in-msgs keyword
followed by a value to indicate the maximum number of ACL
logs that can be generated, exceeding which the generation
of ACL logs is terminated with the seq, permit, or deny
commands. The threshold range is from 1 to 100.
(OPTIONAL) Enter the keyword interval followed by the
time period in minutes at which ACL logs must be generated.
The interval range is from 1 to 10 minutes.
(OPTIONAL) Enter the keyword monitor when the rule is
describing the traffic that you want to monitor and the ACL
in which you are creating the rule is applied to the monitored
interface.
Added support for flow-based monitoring on the MXL
10/40GbE Switch IO Module platform.
Added the support for logging of ACLs on the MXL 10/40GbE
Switch IO Module platform.
Introduced on the MXL 10/40GbE Switch IO Module.