Clo / Lfr Sensor - Barco Galaxy NH-12 Service Manual

Hide thumbs Also See for Galaxy NH-12:
Table of Contents

Advertisement

7.21 CLO / LFR sensor

Description of the CLO / LFR sensor
The CLO / LFR sensor is a light sensor which measures light brightness and the fluctuation of this value (frequency) and the lamp
flicker.
The value can be used to control the light output to a desired value and to correct for the ripple in the light value.
Necessary tools
Torx screwdriver T10
How to remove the CLO / LFR sensor?
1. Remove the covers (see concerning chapter):
-
rear cover
-
top cover
-
folding mirror cover
2. Unplug the connector on the CLO / LFR sensor
3. Remove both fixing screws
Image 7-172
CLO / LFR sensor: fixing screws
4. Slide out the CLO / LFR sensor
How to install the CLO / LFR sensor?
1. Slide in the CLO /LFR sensor
2. Fix the CLO / LFR sensor using both fixing screws
R59770141 GALAXY NH-12 20/02/2008
7. Electronic parts and servicing procedures
115