DRAFT
10. SERVICE MODE
10.8.13
Tilt(F)
A. Use
• Adjusts the amount of loop produced before the ADF registration roller for the front side
of the original fed from the ADF.
• When original jam or skew occurs, use this function for the front side of the original fed
from the ADF.
B. Procedure
• The default setting is 0.
• -5.0 (-5.0 mm) ~ "0 (0 mm)" ~ +5.0 (+5.0 mm)
• Step: 0.25 mm
1. Call the Service Mode to the display.
2. Touch [Scanner Adjustment]
3. Using the [+]/[-] key on the screen or the ten-key pad, enter a setting value and touch
[OK].
10.8.14
Tilt(B)
A. Use
• Adjusts the amount of loop produced before the ADF registration roller for the back side
of the original fed from the ADF.
• When original jam or skew occurs, use this function for the back side of the original fed
from the ADF.
B. Procedure
• The default setting is 0.
• -5.0 (-5.0 mm) ~ "0 (0 mm)" ~ +5.0 (+5.0 mm)
• Step: 0.25 mm
1. Call the Service Mode to the display.
2. Touch [Scanner Adjustment]
3. Using the [+]/[-] key on the screen or the ten-key pad, enter a setting value and touch
[OK].
152
→
[Tilt(F)].
→
[Tilt(B)].
Field Service Ver. 1.0 Feb. 2010