Field Service Ver. 1.0 Feb. 2010

11.4 How to analyze the T30 protocol monitor

• DCS or DIS
• HEX data as printed on page.
• Example: V.17 communication
V17 14400
V17 14400
00:02'55
CED
00:06'64
CSI
00:07'25
DCS
• FIF (Facsimile Information Field)
HEX
0
Data bit
0 0 0 0 0 0 0 0 0
Bit No.
8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 24 23 22 21 20 19 18 17 32 31 30 29 28 27 26 25
Bit No.11= 1, Bit No.12=0 7200 bps
Note
Bit No.15= 1 R8 x 7.7 Lines/mm (Fine Mode)
Bit No.19= 0, Bit No.20=1 Unlimited Paper Length
• Hex-binary conversion list
Hex
Binary
0
0
0
0
1
0
0
0
2
0
0
1
3
0
0
1
[Data Dump - Protocol]
---
MR
FF 03 40 20 20 20 20...
FF 13 83 00 46 88 00...
Means address
1
0
4
1
0 0 0 1 1 0 1 0 0 0 1 0 0 0
↑ ↑
Hex
Binary
0
4
0
1
0
1
5
0
1
0
0
6
0
1
1
1
7
0
1
1
ECM 200x200
FIF (Facsimile Information Field)
FCF (Facsimile Control Field)
= 83: DCS, 80: DIS
Means Last Control Field.
6
8
8
↑ ↑
Hex
Binary
0
8
1
0
0
1
9
1
0
0
0
A
1
0
1
1
B
1
0
1
11. FAX PROTOCOLS
P 1
12.25.2009 14:30
Serial No. XXXXXXXXXXXXX
2
0
0
0 0 0 0 0 0 0 0
Hex
Binary
0
C
1
1
0
1
D
1
1
0
0
E
1
1
1
1
F
1
1
1
181
0
1
0
1

Hide quick links: