10. SERVICE MODE
Two-way communication
Step
6
Encryption setting
1. Select [Service Mode]→[CS Remote Care]→[Basic Setting]→[Encryption].
2. Select [Yes] or [No] according to the necessity of encryption, and touch [OK].
7
Heart Beat *1
1. Select [Service Mode]→[CS Remote Care]→[CSRC Settings]→[Heartbeat Settings].
2. In [Enable Heartbeat], set whether or not to enable Heart Beat communication. (Default: Yes)
3. Select [Interval] and enter a Heart Beat transmission interval (1 to 256 minutes, Default: 30
minutes).
4. In [Enable Fixed Time], set whether or not to enable Heartbeat transmission at a fixed interval.
(Default: Yes)
5. Select [Fixed Time] and enter a Heartbeat transmission interval (1 to 256 minutes, Default: 30
minutes).
8
Proceed to step 10.
9
10
Setting the http server
1. Select [Service Mode]→[CS Remote Care]→[Basic Setting]→[Web Server]
2. Input the server name of the CS Remote Care center, and touch [OK].
3. Select [Service Mode]→[CS Remote Care]→[WebDAV Settings], and make the settings of
communication with the server according to the network environment.
See P.165
11
Enables/disables some special warning and report functions
1. Select [Service Mode]→[CS Remote Care]→[CSRC Settings]→[Switches Settings], and set
whether or not to enable each function.
See P.166
12
Executing the initial transmission
1. Select [Service Mode]→[CS Remote Care]→[Subscribe].
2. Select [Yes], and touch [OK] to start initial transmission.
3. When the machine is properly connected with the center, the "Completed" message will be
displayed.
*1 Heartbeat is a feature that uploads a Heartbeat file to the registered web server at a
specified interval to report that the device is operating. Heartbeat files include total
counter and status information.
162
Field Service Ver. 1.0 Feb. 2010
One-way communication
Procedure
Periodic transmission setting
1. Select [Service Mode]→[CS Remote
Care]→[CSRC Settings]→[Periodic Trans.].
2. In [Enable Trans.], set whether or not to
enable periodic transmission.
(Default: On)
3. Select [Interval], [Time], [Day of the Week] or
[Date] and set the schedule of periodic
transmission.
See P.166
Report setting
1. Select [Service Mode]→[CS Remote
Care]→[CSRC Settings]→[Report Settings].
2. Select the report item and set items that will
be reported to the Center.
See P.166