Field Service Ver. 1.0 Feb. 2010
10.7.5

RX Speed

A. Use
• Set the max. reception speed.
B. Procedure
• The default setting is 33600bps.
2400bps
16800bps
31200bps
10.7.6

ECM RX OFF

A. Use
• Set whether or not to cancel reception ECM (error correction mode).
B. Procedure
• The default setting is No.
Yes
• Yes: Ignores all errors that occur during communication.
• "No": If an error occurs during communication, retransmits the frame, in which the error
occurred.
• If "Yes" is selected, select Yes for RX V34 OFF and MR or MH for the coding system.
10.7.7

Redial V34 Dis.

A. Use
• Set whether to enable or disable V.34 communication when redialing after a communica-
tion error.
B. Procedure
• The default setting is ON.
"ON"
10.7.8

RX V34 OFF

A. Use
• Set V34 OFF during reception.
B. Procedure
• The default setting is No.
Yes
10.7.9

V17 Mod. Permit.

A. Use
• Set whether to enable or disable the V.17 modulation/demodulation mode.
B. Procedure
• The default setting is ON.
"ON"
4800bps
7200bps
19200bps
21600bps
"33600bps"
10. SERVICE MODE
9600bps
12000bps
24000bps
26400bps
"No"
OFF
"No"
OFF
14400bps
28800bps