13. Disconnect the connector [1].
14. Remove two screws [2].
A121F2C061DA
15. Remove the E-ring [1] and bearing
NOTE
• Before removing the holder [3],
[1]
A121F2C062DA
7. OTHER MAINTENANCE ITEM
[2], and remove the holder [3].
attach tape or similar material [4] to
the section shown in the illustration
to prevent the shaft from falling
down and being lost.