CFR to Phase C

A. Use
• Set the wait time between CFR and phase C.
• Adjust this when communication fails.
B. Procedure
• The default setting is 400.
1. Call the Service Mode to the display.
2. Touch [Service Fax Setting]
3. Use [+]/[-] key on the screen to set the wait time and touch [OK].
10.7.16

TX Level

A. Use
• Set the transmission level.
• Adjust this when communication fails.
B. Procedure
• The default setting is -10.
1. Call the Service Mode to the display.
2. Touch [Service Fax Setting]
3. Use [+]/[-] key or 10-key pad on the screen to set the transmission level and touch [OK].
10.7.17

Connect. Timeout

A. Use
• Set the T0 timer (call connection wait time).
• Adjust this when communication fails.
B. Procedure
• The default setting is 55.
1. Call the Service Mode to the display.
2. Touch [Service Fax Setting]
3. Use [+]/[-] key or 10-key pad on the screen to set the call connection wait time and
touch [OK].
10.7.18

CED Level

A. Use
• Set the answer tone output level.
B. Procedure
• The default setting is -43db.
-35db
-41db
10 to 1000 ms (Step: 10)
[CFR to Phase C].
-15 to -4db (Step: 1)
[TX Level].
30 to 120 s (Step: 1)
[Connect. Timeout].
-36db
-37db
-42db
"-43db"
10. SERVICE MODE
-38db
-39db
-44db
-45db
-40db
135