SNMP Traps

The Switch sends traps to an SNMP manager when an event occurs. The following tables outline the
SNMP traps by category.
An OID (Object ID) that begins with "1.3.6.1.4.1.890.1.15" is defined in private MIBs. Otherwise,
it is a standard MIB OID.
Table 149 SNMP System Traps
OPTION
OBJECT LABEL
coldstart
coldStart
warmstart
warmStart
fanspeed
zyHwMonitorFanSpeedOut
OfRange
zyHwMonitorFANSpeedOut
OfRangeRecovered
poe
zyPoePowerPortOverload
(For PoE
zyPoePowerPortShortCircuit 1.3.6.1.4.1.890.1.15.3.59.4.2
models only)
zyPoePowerPortOverSyste
mBudget
zyPoePowerPortOverloadRe
covered
zyPoePowerPortShortCircuit
Recovered
zyPoePowerPortOverSyste
mBudgetRecovered
temperature
zyHwMonitorTemperatureO
utOfRange
zyHwMonitorTemperatureO
utOfRangeRecovered
voltage
zyHwMonitorPowerSupplyV
oltageOutOfRange
zyHwMonitorPowerSupplyV
oltageOutOfRangeRecovere
d
GS2210 Series User's Guide
OBJECT ID
1.3.6.1.6.3.1.1.5.1
1.3.6.1.6.3.1.1.5.2
1.3.6.1.4.1.890.1.15.3.26.2.1
1.3.6.1.4.1.890.1.15.3.26.2.6
1.3.6.1.4.1.890.1.15.3.59.4.1
1.3.6.1.4.1.890.1.15.3.59.4.3
1.3.6.1.4.1.890.1.15.3.59.4.5
1.3.6.1.4.1.890.1.15.3.59.4.6
1.3.6.1.4.1.890.1.15.3.59.4.7
1.3.6.1.4.1.890.1.15.3.26.2.2
1.3.6.1.4.1.890.1.15.3.26.2.7
1.3.6.1.4.1.890.1.15.3.26.2.3
1.3.6.1.4.1.890.1.15.3.26.2.8
Chapter 37 Access Control
DESCRIPTION
This trap is sent when the Switch is
turned on.
This trap is sent when the Switch
restarts.
This trap is sent when the fan speed goes
above or below the normal operating
range.
This trap is sent when the fan speed is
recovered from the out of range to
normal operating range.
This trap is sent when the port is turned
off to supply power due to overloading.
This trap is sent when the port is turned
off to supply power due to short circuit.
This trap is sent when the port is turned
off to supply power because the
requested power exceeds the total PoE
power budget on the Switch.
This trap is sent when the port is turned
on to recover from an overloaded state.
This trap is sent when the port is turned
on to recover from a short circuit.
This trap is sent when the port is turned
on to recover from an over system
budget.
This trap is sent when the temperature
goes above or below the normal
operating range.
This trap is sent when the temperature is
recovered from the out of range to
normal operating range.
This trap is sent when the voltage goes
above or below the normal operating
range.
This trap is sent when the power supply
voltage is recovered from the out of
range to normal operating range.