Download Print this page

Toshiba e-studio166 Service Handbook page 98

Multifunctional digital systems
Hide thumbs Also See for e-studio166:

Advertisement

[C] Reproduction ratio adjustment of the secondary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3)
Press [0] and [9] simultaneously to enter the normal mode.
(4)
Make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment.
(5)
Press [0] and [5] simultaneously to enter the adjustment mode.
(6)
Measure the distance C from 200 mm to 400 mm of the copied image of the ruler.
(7)
Check if the distance C is within the range of 200±0.5 mm.
(8)
If not, use the following procedure to change values and repeat the steps (3) to (7) above.
(Adjustment Mode)
(Key in a value (acceptable values: 76 to 181))
Press the [INTERRUPT] button (stored in memory: The density LED blinks.).
played.)
*The smaller the adjustment value is, the lower the reproduction ratio becomes (0.189 mm/step).
Be sure not to perform any operations while the density LED is blinking.
50
e-STUDIO163/166/203/206
ADJUSTMENT
(Key in the code [340])
Copied image of the ruler
100
150
200
Fig. 3-10
3 - 14
06/04
(Adjustment Mode)
[START]
250
300
350
C
Feeding direction
© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
("AJ" is dis-
400

Hide quick links:

Advertisement

loading

This manual is also suitable for:

E-studio163E-studio203E-studio206