Download Print this page

Toshiba e-studio166 Service Handbook page 97

Multifunctional digital systems
Hide thumbs Also See for e-studio166:

Advertisement

[B] Image position adjustment of the primary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Place a ruler on the original glass with its leading edge pushed against the rear side and its side
along the original scale on the left.
(3)
Press [0] and [9] simultaneously to enter the normal mode.
(4)
Make a copy at the mode of A3 (LD), 100% and standard drawer of the equipment.
(5)
Press [0] and [5] simultaneously to enter the adjustment mode.
(6)
Measure the distance B from the left edge of the paper to 10 mm of the copied image of the ruler.
(7)
Check if the distance B is within the range of 10±0.5 mm.
(8)
If not, use the following procedure to change values and repeat the steps (3) to (7) above.
(Adjustment Mode)
(Key in a value (acceptable values: 121 to 136))
Press the [INTERRUPT] button (stored in memory: The density LED blinks.).
played.)
*The smaller the adjustment value is, the more the image is shifted to the left and the distance B
become narrower (0.169 mm/step).
Be sure not to perform any operations while the density LED is blinking.
© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
(Key in the code [306])
Copied image of the ruler
Feeding direction
Fig. 3-9
3 - 13
06/04
(Adjustment Mode)
[START]
("AJ" is dis-
e-STUDIO163/166/203/206
ADJUSTMENT
3

Hide quick links:

Advertisement

loading

This manual is also suitable for:

E-studio163E-studio203E-studio206