Download Print this page

Toshiba e-studio166 Service Handbook page 120

Multifunctional digital systems
Hide thumbs Also See for e-studio166:

Advertisement

[ 2 ] Operation
Note:
Note:
When adjusting output of high-voltage transformer, make sure to use the high-voltage trans-
former jig.
Connect the digital testers as described in "[1] Preparation", and follow the procedure on the next
page to adjust the output from the main charger, developer bias charger, transfer charger and sepa-
ration charger.
<Keys to press>
[0][5]
[POWER]
Front cover opening/
closing switch
1
[Digital keys]
[START]
[START]
Reproduction ratio button
([25%] / [200%])
[INTERRUPT]
[POWER]
OFF/ON
e-STUDIO163/166/203/206
ADJUSTMENT
: Press one time.
: Enter the code.
: Current adjustment value is displayed.
: Adjustment start.
: Adjust the value to satisfy the following table.
Code
Adjustment value
Code
Adjustment value
Code
Adjustment value
: Adjusted value is stored in memory.
Return to 1 to enter the other adjustment code.
<Display>
Developer bias
Main charger
205
-341±5V
-448±5V
Transfer charger
Leading edge
Center area
area of paper
of paper
220
1005±106mV
1086±106mV
Separation charger
Leading edge
Center area
area of paper
of paper
233
-566±54mV
-566±54mV
Fig. 3-22
© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
3 - 36
210
Trailing edge
area of paper
221
222
845±71mV
Trailing edge
area of paper
234
235
-391±36mV