17)Faded image (low density, abnormal gray balance)
Defective area
Toner empty
Auto-toner circuit
Toner motor
Toner cartridge
Developer material
Developer unit
Main charger
Drum
Transfer charger
High-voltage transformer
Discharge LED
© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
Fig. 5-17
Step
Check items
1
Is "ADD TONER" symbol lit?
2
Is there enough toner in the car-
tridge?
3
Is the toner density in the developer
material too low?
4
Is the toner motor working normally?
5
Is there any problem with the toner
cartridge?
6
Has the developer material reached
its PM life?
7
Is the magnetic brush in proper con-
tact with the drum?
8
Is the developer sleeve pressuriza-
tion mechanism working?
9
Is the main charger dirty?
10
Is "film-forming" occurring on the
drum surface?
11
Has the drum reached its PM life?
12
Is the transfer charger wire cut off?
13
Is the setting for the high-voltage
transformer proper?
14
Are the connectors of the high-volt-
age harness securely connected? Is
the harness open circuited?
15
Are the connectors of discharge LED
harness securely connected?
5 - 37
Prescription
Replace the toner cartridge.
Check the performance of the auto-
toner circuit.
Check the toner motor and the motor
drive.
Replace the toner cartridge.
Replace the developer material.
Check the installation of the devel-
oper unit.
Adjust the doctor-sleeve gap and
polarity.
Check the mechanism.
Clean it or replace the needle elec-
trode and main charger grid.
Clean or replace the drum.
Replace the drum.
Replace the transfer charger wire.
Adjust the output from the high-volt-
age transformer.
Reconnect the harness securely.
Replace the high-voltage harness.
Reconnect the harness securely.
e-STUDIO163/166/203/206
TROUBLESHOOTING