(6) Adjustment of the Multi Bypass Table Reference Position

Requirement
1074D089
1139D025AA
<15/18 cpm copier>
1139D026AA
<23 cpm copier>
1151D024AA
• Ready a test chart (A3 or 11" × 17") as shown on the
left. Draw a line on the chart at a point 20 mm from
the right edge as shown.
• Dimension A on the copy should measure
20 ± 2.0 mm.
1. Place the test chart face down on the Original
Glass and align its rear left corner with the
marker on the Original Width Scale on the left side
of the platen.
Then, lower the Original Cover.
2. Using the Multi Bypass Table, make two full size
copies.
3. Using the second copy, compare the position of the
reference line on the copy with that on the test
chart.
4. If the line does not meet the requirement, loosen
the screws (23 cpm copier: three screws/15/18
cpm copier: two screws) that secure the Multi
Bypass Table and move the Table as necessary in
the direction of the arrows.
NOTE
If dimension A on the copy is smaller than 18 mm,
move the Table to the front. If it is more than 22 mm,
move the Table to the rear.
When an Automatic or Duplexing Document Feeder is
mounted, it involves changing the Original Glass. This
in turn results in the position of the Original Length
Scale being slightly shifted toward the rear. This is cor-
rected by installing the Original Positioning Plate.