FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 GENERAL, MECHANICAL/ELECTRICAL
98.04.24
1174SBM0502A
5-2.

Imaging Unit Toner Recycling

The copier is provided with a toner recycling mechanism. The toner, which has been
scraped off the surface of the PC Drum by the Cleaning Blade and collected in the Cleaning
Unit, is conveyed by the two Toner Recycling Coils to the Toner Supply Port and, from there,
it is returned back to the Developer Mixing Chamber of the Developing Unit.
One of the gears of the Toner Recycling mechanism receives drive through a gear at the
rear end of the PC Drum.
Toner Supply Port
Toner Recycling Coil
Toner Recycling Path
Bevel Gears
1139M013AA
Toner Recycling Coil
1174SBM0503A
5-3.

Imaging Unit Fuse

The Imaging Unit is provided with a fuse called the I/U Fuse. When a new Imaging Unit is
installed in the copier and the Power Switch turned ON, an I/U Set signal is output causing
the copier to start the starter setup sequence and ATDC Sensor automatic adjustment.
When the starter setup sequence is completed normally, an I/U Fuse Blow signal is output
to blow the I/U Fuse. Once the I/U Fuse is blown, the I/U Set signals are no longer output.
This means that the starter setup sequence and ATDC Sensor automatic adjustment will
not be carried out when the Power Switch is thereafter turned ON.
When Fuse is
When Fuse is
Control Signal
WIRING DIAGRAM
not Blown
Blown
Fuse
PWB-A PJ10A-6
H
L
2-I
M-14