Adjustment Requirements List - Minolta EPI 054 User Manual

Table of Contents

Advertisement

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13
3-2.

ADJUSTMENT REQUIREMENTS LIST

Adjustment Item
Max. Exposure Lamp
100 to 127V areas: 81 ± 1 V
Voltage
200 to 240V areas: 162 ± 2 V
Optimum Exposure
Kodak Gray Scale:
Setting in the Manual
no image of the 1st step,
Exposure Mode
faint image of the 2nd step
Optimum Exposure
Setting in the Auto
Exposure Mode
Multi Bypass Table
(100 %) 20 ± 2 mm
Reference Position
1st Drawer Reference
(100 %) 20 ± 2 mm
Position 1
2nd Drawer Reference
(100 %) 20 ± 2 mm
Position
Full Size Leading Edge
(100 %) 20 ± 1.5 mm
Registration
Enlargement Leading
(200 %) 40 ± 3 mm
Edge Registration
Reduction Leading
(50 %) 10 ± 1.5 mm
Edge Registration
Image Leading Edge
0.5 to 6.5 mm
Erase Width
(100%) 1.0~6.5mm
(200%) 0.5 ~11mm
(50%) 0.5~6.5mm
Image Erase Lamp
1 ± 0.5 mm
Position
Adjustment of the
Original Size Detecting
Board
1 23 cpm copier only
Control Panel Indication
Different indications are given on the control panel (Zoom Ratio Indicator, etc.) between
15,18 and 23 cpm copier. For details, see Service Mode in Switches on PWBs.
Requirements
Control panel
Control panel
Control panel
Multi Bypass Table
Drawer Front Panel
Drawer Front Panel
Control panel
Control panel
Control panel
Control panel
Adjusting Screw for
Image Erase Lamp
position
Control panel
D-50
Ref.
Adjusting Point
Page
D-52
D-55
D-56
D-59
D-60
D-60
D-62
D-64
D-65
D-66
D-68
D-71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep2030Ep1085Ep1054

Table of Contents