FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13
When using the testers, voltmeters, or multimeters which show only the mean value, not
Rms values, carry out the following procedure.
1. Measure the line voltage.
2. Referring to the Mean Value Chart corresponding to each voltage area, see the figure
under the voltage obtained in step 1.
If the line voltage is 125 V and Rms value is 81 V, for example, the mean value is 54.5 V.
Therefore, it is recommended that the voltage be adjusted so that the mean value is set as
close to 54.5 V as possible.
MEAN VALUE
CHART FOR 115/120/127V AREAS
V
104
105
106
Rms
81.0
60.7
60.3
60.0
V
114
115
116
Rms
81.0
57.3
57.0
56.8
V
124
125
126
Rms
81.0
54.7
54.5
54.3
V
134
135
136
Rms
81.0
52.7
52.5
52.2
107
108
109
110
59.7
59.2
59.0
58.5
58.2
117
118
119
120
56.5
56.2
56.0
55.7
55.5
127
128
129
130
54.2
54.0
53.7
53.5
53.2
137
138
139
140
52.1
52.0
51.7
51.5
VALUE
D-53
111
112
113
MEAN
58.0
57.7
VALUE
121
122
123
MEAN
55.2
55.0
VALUE
131
132
133
MEAN
53.0
52.8
VALUE
MEAN