Cleaning Of The Pre-Fusing Guide Plate; Removal Of The Upper Fusing Roller - Minolta EPI 054 User Manual

Table of Contents

Advertisement

FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13

(2) Cleaning of the Pre-Fusing Guide Plate

1139D190AA

(3) Removal of the Upper Fusing Roller

1139D191AA
1139D192AA
1151D011AA
1151D012AA
1. Using a soft cloth dampened with alcohol, wipe
clean the Guide Plate.
1. Remove two screws and the Fusing Unit Front
Cover.
2. Remove two screws and the Fusing Unit Upper
Cover.
3. Remove two screws and the Upper Paper Separa-
tor Fingers Unit.
4. Remove four Cord Holders of the Fusing Ther-
mistor.
5. Remove one screw and the Fusing Thermistor.
6. Remove the screw and clamp that secure the
Lamp harness at the front of the copier.
D-41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep2030Ep1085Ep1054

Table of Contents