FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13
1139D034CA
1139D036CA
1139D019CA
4. Press 10-keys "4" and press the Start Key. (Then,
the Magnification Ratio Indicator shows "A4" and
the Multi-Copy Display, the current setting value.)
5. Press the Clear Key to clear the current setting
value.
6. With the old setting value used as reference, enter
the new setting value using the appropriate 10-
keys.
NOTE
If dimension A on the copy is smaller than 18.5 mm,
decrease the setting value.
If dimension A on the copy is greater than 21.5 mm,
increase the setting value.
7. Press the Start Key to validate the setting.
8. Press the Panel Reset Key twice (or turn OFF the
Power Switch) to return the copier back to the nor-
mal mode.
9. Make two single copies and check for leading edge
registration on the second copy. (If it does not meet
the requirement, perform steps 3 through 10
again.)